10. Safety system
MiR250 Shelf Carrier User Guide (en) 03/2021 - v.1.4 ©Copyright 2021: Mobile Industrial Robots A/S.
106
Field set when driving forward
The following table shows speeds and the field range when driving forward. The table
describes the length of the Protective field in front of the robot in different cases. Each case
is defined by a speed interval that the robot may operate at. The colors and cases in
correspond to the field set shown in
.
Case
Speed
Protective field range
Comments
1
0.0 to 0.10 m/s
0-80 mm
When pivoting
2
0.10 to 0.30 m/s
0-180 mm
3
0.30 to 0.50 m/s
0-360 mm
4
0.50 to 0.90 m/s
0-780 mm
5
0.90 to 1.30 m/s
0-1350 mm
6
1.30 to 1.70 m/s
0-2100 mm
7
1.70 to 2.10 m/s
0-2850 mm
Forward at max. speed
Table 10.1.
Ranges of the robot's Protective fields within its forward speed interval cases
Figure 10.5. The illustration shows the field set contours when the robot drives forward. The range of the active
field changes with the robot's speed.