Interleaf EP5000/EP4000 SWITCHES ON PWBs, TECH. REP. SETTINGS
97.04.01
S-39
1156SBS050410A
10. Level History
D
This function is used to show and set the various level histories which were changed according to the
operating conditions of the copier and user requirements.
Tech. Rep. Mode
"
Level History
Touch Panel
Display
Setting
Level History
Touching the Level History key will show the various level histories as detailed
below. Of all data displayed, only that for “ATDC Ref. Value” and “Fuser
Temp. Control” can be changed.
– ATDC Ref. Value –
D
Change this data when the RAM Board has been changed or a Developing
Unit from another copier has been installed.
– Fuser Temp. Control –
D
Change this data if fusing performance becomes poor due to the operating
environment and the paper being used.
<Level History 1/2>
Display
Variable Range
Incre-
ments
Description
ATDC Ref. Value
ATDC Target Level
ATDC Current Level
2 step
0.5 (%)
0.5 (%)
F8 adjusted value
Target ATDC level
Current ATDC level
2 to 254
1.0 to 9.0 (%)
1.0 to 9.0 (%)
Vg Default Level
Vg Current Level
30 (V)
30 (V)
Initial grid voltage
setting
Grid voltage correc-
tion value due to
changes with time
400 to 850 (V)
400 to 850 (V)
<Level History 2/2>
Display
Variable Range
Incre-
ments
Description
Fuser Temp. Control
Fuser Temp. Current
10 (
°
C)
10 (
°
C)
Target fusing tem-
perature
Current fusing tem-
perature
180 to 200 (
°
C)
160 to 220 (
°
C)
Expo. Default Level
Expo. Current Level
1 (V)
1 (V)
Initial Exposure
Lamp level setting
Exposure Lamp lev-
el correction value
due to changes with
time
49 to 71 (V)
49 to 71 (V)
Toner Replenishing
Time
10 steps
Cumulative time of
toner replenishing
0 to 1270 (mm)