Interleaf EP5000/EP4000 SWITCHES ON PWBs, TECH. REP. SETTINGS
97.04.01
S-6
<Clearing Procedures>
D
Initialize Points PJ2
1. Turn OFF the Power Switch.
2. With PJ2 closed, turn ON the Power Switch.
3. In approx. 5 sec. open PJ2.
4. Check that the message “Initialize completed” is shown on the Touch Panel, then touch “Enter.”
D
Memory Clear Test Point TP3
1. Turn OFF the Power Switch.
2. With the circuit across TP1 and 3 closed, turn ON the Power Switch.
3. In approx. 5 sec. open the circuit across TP1 and 3.
4. Check that the message “Memory Clear completed” is shown on the Touch Panel, then touch “Enter.”
NOTE
D
If an erratic operation or display occurs, perform the clearing procedures in the order of PJ2 and TP3.
D
When memory clear has been performed, make the necessary settings again.
<List of Data Cleared by Switches and Points>
Clearing Method
Data Cleared
Front Door
Open/Close
Trouble Reset
Switch
(S1)
Initialize
Switch
(PJ2)
Memory Clear
Test Point
(TP3)
Misfeed display
f
f
f
f
Malfunction display (except
Exposure Lamp and fusing
system)
f
f
f
f
Malfunction display (all includ-
ing Exposure Lamp and fusing
system)
*
f
f
f
Erratic operation/display
*
*
f
f
User mode
*
*
*
f
Service mode
*
*
*
f
F5/F7 setting values
*
*
*
f
System Input
*
*
*
f
Accessory Test
*
*
*
f
Level History
*
*
*
f
Adjust mode
*
*
*
f
f
: Cleared (initialized)
*
: Not cleared: