3.5.1
Replacing a Camlock
a.
Camlock replacement can be achieved as follows:
•
Open the camlock lever and using a pin punch and hammer drive the camlock pin out.
•
Once the camlock pin has been removed the camlock pressure block can be removed and
replaced if needed.
Note
When the camlocks are closed they must hold the shafts firmly with no slippage. If the
camlock does not hold the shafts firmly in place then pressure blocks should be replaced
.
•
To reassemble the camlock, fit the pressure block to the camlock lever.
•
Place the camlock lever with pressure block fitted into position within the camlock body
then press the camlock pin into place.
3.5.2
Removing the Shafts
a.
To remove the shafts from the detector firstly open the detector body as described in
Section
3.1 – Opening the Detector Body
. Once completed:
•
Lift the shafts clear of the detector.
Figure 72: Removing Camlock Pin
Figure 73: Fitting Camlock Pin