Align the cable six way ribbon with its connector. Slide the connector locking bail
outwards to accept the cable six way ribbon.
•
Insert the cable six way ribbon into the connector then push the locking bail to secure.
•
Connect the battery connector to the main PCB.
•
Make sure all connectors are firmly in place and all wires and cables are positioned so
that they will not cause obstruction or get damaged when the two halves of the main
body are fitted together.
•
Fit the two screws (12mm) to the interface PCB.
Figure 45: Connecting Battery Connector
First Pull locking bail out to accept Cable
Push locking bail in
Figure 44: Connecting Six Way Ribbon Cable
Second insert Six Way Ribbon Cable
Figure 46: Interface PCB and Coil Connector Nut