Note
Do not move the detector with the hinge cover removed as this may result in the spring
latch hinge and the latch hinge becoming disengaged.
•
Confirm coil connector is tight and check the coil cable and the wiring loom are located
into the cable router.
•
Check the latch and spring latch hinge are connected as shown in Figure 26. If the latch
and spring have become disconnected they must be reconnected. It is possible to
reattach the eyelet of the spring to the pin of the latch hinge through the opening under
the hinge cover. Alternately the detector body can be opened to reattach the spring to
the latch.
•
Fit the hinge cover and make sure the protrusion on the underside of the hinge cover
engages into the slot on the detector body near the hinge. Fit the two screws (45mm)
into the hinge cover and tighten.
•
•
•
•
•
•
•