3.4.6
Fitting the Coil
a.
With practice and a pull through tool it is possible to fit the coil to the detector without
opening the detector body.
b.
Open the detector body as described in Section
3.1 - Opening the Detector Body
. Once
completed:
•
Remove the shaft and coil from the detector. Section
3.4.2 -
Removing the Coil
•
Remove the cover shaft hinge from the shafts.
•
Connect the coil cable pull-through to the coil connector. Alternatively, a piece of string
could be used to thread the coil cable into the shafts.
•
Feed the coil cable pull-through into the coil end of the lower shaft and out through the
top (hinge end) of the upper shaft. Feed the coil cable until the coil connector is exposed.
•
Insert the pin coil cable into the end of the upper shaft so that the pin engages into the
turns of the coil cable within the shaft. Turn the pin counter clockwise to lock it into
place.
Figure 66: Threading Coil Cable through Shafts
Figure 67: Fitting Pin Coil Cable and Cover Shaft Hinge