36
•
Separate the pivot lower shaft from the pivot coil yoke. Gently feed the coil cable through
the pivot lower shaft removing the pivot shaft from the coil cable. Do not stretch the coil
cable.
•
Pull the pivot coil yoke off the coil and carefully thread the coil cable through the pivot
coil yoke. If required remove the O-ring from the coil.
3.4.5
Fitting the Coil Pivot
a.
To fit the coil pivot, firstly remove the coil from the detector as described in section
3.4.2 - Removing the Coil
. Once completed:
•
Fit the O-ring to the coil as shown in Figure 60.
Pivot Coil Yoke
Pivot Lower Shaft
Figure 58: Removing Pivot Lower Shaft
Figure 59: Removing Pivot Coil Yoke
O-Ring