F3 COMPACT Service Manual
_______________________________________________________________________________________________________________________
19
Note
The hinge cover holds the latch hinge and spring latch hinge in place. When the hinge cover
is removed the spring may unintentionally disconnect from the latch.
•
Ensure the battery lid is closed.
•
Connect the speaker connector to the PCB connector. Check all other connectors and
cables are connected.
•
Check the O-ring in the detector body is clean, lightly greased and correctly positioned.
•
Check all internal cables and wires are correctly positioned and will not be trapped.
•
The coil cable must be located within the shaft hinge so that it is not trapped or damaged
when the halves of the detector body are fitted together. In particular, the coil cable
must not be positioned above the hinge screw bosses.
Coil Cable
Must Not
be
above these
areas
Figure 21: Coil Cable Position in Shaft Hinge
Speaker Connector
Figure 20: Connecting Speaker
Speaker Assembly