![Minebea Intec Maxxis 5 Original Installation Manual Download Page 85](http://html1.mh-extra.com/html/minebea-intec/maxxis-5/maxxis-5_original-installation-manual_1801172085.webp)
Example:
Platform with 6-wire connection
+ Meas.
– Meas.
+ Supply
+ Sense
– Sense
– Supply
Ground
analog
black
blue
green
grey
red
white
GNDA
PR 5900
PR 5900
1
2
3
4
①
Screen
②
Screen clamping rail or cable gland
③
Equipotential bonding conductor
④
or
4.6.5
PR 5900/12 digital inputs and outputs
The plug-in card has 4 passive opto-decoupled inputs for process control.
The plug-in card also has 4 relay outputs with potential-free change-over contacts for
process control.
The card is inserted in the option 1 and/or option 2 slot.
A maximum of 2 PR 5900/12 plug-in cards can be installed.