Description
Data
Linearity
<0.003%
Temperature coef. Zero
(Tk
o
)
<0.05 µV/K RTI,
<0.004%/10K @ 1 mV/V
Temperature coef. Vst
(Tk
span
)
<±4.0 ppm/K
Cable length
Max. 300 m
Cable type
6
‑
wire with screen for entire cable and screen for measure-
ment cables, e.g., PR 6135/..
Dimensions (LxWxH)
85×50×25 mm
Weight
Approx. 60 g
4.6.4.1
Analog connections
There are up to 2 connections on the housing rear panel for analog load cells or analog
platforms (e.g., CAPP series) depending on the model. The supply voltage is protected
against short circuit and overload.
Note:
Do not shorten
the load cell cable. Connect the prepared cable end and roll up the
remaining cable.
Process Controller Maxxis 5 PR 5900
4 Device installation
EN-74
Minebea Intec