Plug-in connections inside the device for load cells, inputs/outputs, LAN connection,
serial interfaces
-
Calibration using PC tool (browser/VNC)
-
Calibration using weights according to the mV/V method or directly using load cell
data (smart calibration)
-
Software coniguration of the interface cards, e.g., for remote display or printer
-
Analog test for the weighing electronics
-
Overwrite protection:
-
Via a maximum of 4 CAL switches (two on the main board and one each on the
weighing electronics board)
-
Via software
3.2.1
Communication protocols
For the internal RS
‑
232:
-
Remote display protocol
-
Printer
-
ModBus protocol
-
xBPI protocol
-
SBI protocol
-
EW-Com protocol
Field bus slave (accessories):
-
PR 1721/51 ProiBus
‑
DP
-
PR 1721/54 DeviceNet
-
PR 1721/55 CC-Link
-
PR 1721/56 ProiNet I/O
-
PR 1721/57 EtherNet
‑
IP
-
PR 1721/76 ProiNet I/O 2-port
-
PR 1721/77 EtherNet
‑
IP 2-port
For the internal LAN interface:
-
ModBus-TCP
-
Ethernet TCP/IP
-
OPC
Process Controller Maxxis 5 PR 5900
3 Process controller
EN-12
Minebea Intec