Preparing for the Heaters
Changing the Temperature Settings for the Heaters
Set the heater temperature.
Depending on the media and the profile to use, set the heater temperature.
• It may take several minutes to tens of minutes for the set temperature to be reached, depending on the ambient
temperature.
1
Press the
key.
2
Press the
key.
3
Press
to set the temperature of
each heater.
Heater selecting
: Select with
Temperature setting : Set with
• The heater starts to get hot.(The [HEAT] lamp lights in orange.)
• When the heater temperature reaches the set temperature, the
[HEAT] lamp goes off and the [CONSTANT] lamp lights in green.
4
Press the
key to end the setting.
Checking the Heater Temperature
1
Press the
key.
• The current heater temperature is displayed.
2
Press the
key at the end of confirmation.
• The screen returns to LOCAL.
• You can change the temperature set here also in [HEATER] of the [SETUP] menu. (
P.3-4)
• The Heater temperature is controllable at the RIP side if the RIP in use has a function controllable.
(For the setting procedures, refer to the instruction manual of the RIP in use.)
• Use this machine under 20 to 30
°
C. The temperature may not reach the set value due to the
environmental temperature condition.
PRE
PRT
POS T
3 5
°
C
4 0
°
C
5 0
°
C
Heater temperature
confirming display
Current heater temperature
OF F
OF F
OF F
( 2 3
°
C
2 3
°
C
2 3
°
C )
Heater temperature set in
this machine
4 0
°
C
4 0
°
C
5 0
°
C
( 2 3
°
C
2 3
°
C
2 3
°
C )
The settable temperature
of POST: 20 to 70°C
The settable temperature of
PRE and PRT: 20 to 60°C
PRE
PRT
POS T
3 5
°
C
4 0
°
C
5 0
°
C