5-18
Message
Cause
Solution
The media width has not been detected
correctly.
• Check the media set position.
(
P.2-25)
• Clean the media sensor. (
P.4-4)
The media thickness could not be
detected correctly.
• Enter the media thickness manually.
(
P.2-19)
• Perform media detection again.
A HDC position counter error occurred.
• Turn off the main power to the machine
and turn it on after a while.
If the same error message appears
again, contact your local distributor to call
for service.
Y-origin could not be detected.
Abnormal linear scale.
The media is set outside the proper
area.
• Check the media set position.
(
P.2-25)
The value of the negative pressure sen-
sor is abnormal.
• Perform “PRESSURE ADJUST”
(
P.5-7) of the maintenance. If you
cannot adjust it to the normal value, or,
even if you perform, it may be displayed,
contact your local distributor to call for
service.
The value of the positive pressure sen-
sor is abnormal.
The liquid level sensor abnormality of
the sub tank has been detected.
• Turn off the main power to the machine
and turn it on after a while.
If the same error message appears
again, contact your local distributor to call
for service.
Though a certain amount was con-
sumed, there is no change in the sub
tank sensor High.
• Perform “SUB TANK” (
P.5-6) of the
maintenance. Even if you performed this,
when the message is displayed, contact
your local distributor to call for service.
Though a certain amount was con-
sumed, there is no change in the sub
tank sensor Low.
Overflow from the sub tank has been
detected.
Ink could not be supplied to the sub
tank.
• Perform “SUB TANK” (
P.5-6) of the
maintenance. Also check the remaining
amount of ink in the ink bottle. Even if you
performed this, when the message is dis-
played, contact your local distributor to
call for service.
Starting of the negative pressure control
has an abnormality.
• Perform “PRESSURE ADJUST”
(
P.5-7) of the maintenance. If you
cannot adjust it to the normal value, or,
even if you perform, it may be displayed,
contact your local distributor to call for
service.
The negative pressure cannot be kept
properly
Starting of the positive pressure control
has an abnormality.
E RROR 5 0 c
ME D I A W I D T H S E N SOR
E RROR 5 1 0
T H I C K N E S S D E T E C T
E RROR 5 0 9
HDC POSCN T
E RROR 5 0 a
Y OR I G I N
E RROR 5 0 f
L - SCA L E B L ACK
E RROR 5 1 6
ME D I A S E T POS I T I ON L
E RROR 5 1 6
ME D I A S E T POS I T I ON R
E RROR 5 1 9
N EGA T I V E P . S E N SOR
E RROR 5 1 a
POS I T I V E P . S E N SOR
E RROR 6 1 7
S U B T A N K S NN : 1 2 3 4 5 6 7 8
E RROR 6 1 8
T A N K l e v e l H : 1 2 3 4 5 6 7 8
E RROR 6 1 9
T A N K l e v e l L
: 1 2 3 4 5 6 7 8
E RROR 6 1 a
OV E R F L OW
: 1 2 3 4 5 6 7 8
E RROR 6 1 b
S U P P L Y I N K : 1 2 3 4 5 6 7 8
E RROR 6 1 c
N EGA T I V E P . CON T RO L
E RROR 6 1 d
N EGA T I V E P . N o t E n o u g h
E RROR 6 1 e
N EGA T I V E P . OV E R
E RROR 6 1 f
POS I T I V E P . CON T RO L