![MIMAKI UJV500-160 Operation Manual Download Page 170](http://html1.mh-extra.com/html/mimaki/ujv500-160/ujv500-160_operation-manual_1800361170.webp)
4-40
Replacing the mist filter
Replace it once a month.
1
Pull out the mist filter ASSY located at the rear surface of the main body.
• There are 5 mist filter ASSY at the rear surface of the main body (parts indicated with circles in the
figure).
• Put your finger on the hole of the bottom surface, and pull out the mist filter ASSY downward.
2
Removed the used filter.
(1)
Slide the filter holder a little, and remove it.
(2)
Removed the used filter.
• Ink at printing adheres to the mist filter ASSY.
When replacing the filter, it is recommended
to perform the work with a sheet of paper
placed.
Filter