When Nozzle Clogging Cannot Be Solved
4-17
1
1
1
4
Routine Maintenance
5
Press the
key.
6
Clean the cap rubber and cap rubber cover.
• Wipe off the ink sticking to the cap rubber and cap rubber
cover with a clean stick dipped in cleaning solution for
maintenance. Wipe off so that cleaning solution for
maintenance will not remain.
• At this time, the discharge passage is cleaned automatically.
7
Press the
key.
8
Fill up the cap with cleaning solution for
maintenance, using a dropper.
• Fill the cap with the cleaning solution just before the
solution overflows from the cap.
9
Close the lower right maintenance cover then press
the
key.
10
Press
to set the time for the cleaning
solution to be left as it is.
•
Set value
: 1 to 15 minutes (Unit: minute)
• Until wiper cleaning is competed, [COMPLETED (NEXT): ENT] is displayed on the screen. After
the work up to the step 6 is completed, press the
key. If you press the
key
before cleaning is completed, the machine moves to the next washing procedure.
• Until washing liquid is filled, [COMPLETED (NEXT): ENT] is displayed on the screen. After
the work up to the Step 8 is completed and you close the front cover, press the
key. If you press the
key before washing liquid is filled, the carriage returns to
the original position.
CAP C L EAN I NG
COMP L E T ED ( NEX T ) [ ENT ]
Cap rubber
Cap rubber
cover
F i l l
t h e
l i q u i d .
COMP L E T ED ( NEX T ) [ ENT ]
L EAV I NG T I ME
=
1m i n
L EAV I NG T I ME
=
2m i n