OPERATION

To  reduce  the  risk  of  injury,  wear  safety  goggles  or  glasses

with  side  shields.

WARNING!

Using  the  Temperature  Control  Switch  (Fig.  1-4)
Cat. No. 8975 (Fig. 1)

Dual temperature control heat guns are provided with a 3 position rocker

switch. Place the switch in the center position for “Low” range or press

in  the  lower  position  of  the  switch  completely  for  “High”  range.  The

markings  on  the  switch  correspond  to  these  positions:

Cat. No. 8977 (Fig. 2)

Variable temperature model heat guns are marked “O” for OFF and “l” for

ON. Temperature  is  controlled  by  turning  the  end  cap  in  the  directions

dictated  by  the  arrows.

Fig. 1

Fig. 2

Cat. No. 8978 (Fig. 3)

Electronic  temperature  control  system  heat  guns  allow  the  tool  to  pro-

duce a greater concentration of heat at the nozzle, allowing the use of

various  accessory  nozzles.

Fig. 3

Heat adjustment knob

On  /  off  switch

TOOL ASSEMBLY

Installing  Reduction  Nozzles

Reduction  nozzles  are  used  to  intensify  the  application  of  heat  in  a

specific area.
For reduction nozzle Cat. No. 49-80-0297:
1. To install the reduction nozzle to the heat gun, slide the nozzle onto

the heat gun nose.

2. Adjust heat, distance and length of application as necessary.
For  reduction  nozzles  Cat.  No.  49-80-0305,  49-80-0306  (For  use  with

electronic controlled heat guns 8978, 8986-20 and 8988-20 only):
1. To install the reduction nozzle to the heat gun, align the grooves on

the nozzle with the grooves on the heat gun nose.

2. Slide the nozzle onto the nose.
3. Adjust heat, distance and length of application as necessary.

Installing  Slit  and  Cutting  Nozzles

The slit nozzle Cat. No. 49-80-0308 is used for lap welding. The cutting

nozzle Cat. No. 49-80-0309 is used as a heated cutting edge.

NOTE:

  The  reduction  nozzle  Cat.  No.  49-80-0305  is  needed  as  an  at-

tachment  for  the  slit  and  cutting  nozzles.  (For  use  with  electronic  con-

trolled heat guns 8978, 8986-20 and 8988-20 only):
1. To install the reduction nozzle to the heat gun, align the grooves on

the nozzle with the grooves on the heat gun nose and slide the nozzle

onto the nose.

2. Slide the slit or cutting nozzle onto the reduction nozzle.
3. Adjust  heat,  distance  and  length  of  application  as  necessary.

Installing  Air  Directing  Nozzles

Air  directing  nozzles  are  used  to  change  the  direction  of  the  airflow.
For  hook  nozzle  Cat.  No.  49-80-0292,  deflector  Cat.  No.  49-80-0293,

air  spreader  Cat.  No.  49-80-0294,  soldering  reflector  nozzle  Cat.  No.

49-80-0307:
1. To install an air directing nozzle to the heat gun, slide the nozzle onto

the heat gun nose.

2. Adjust  heat,  distance  and  length  of  application  as  necessary.

For air reflector Cat. No. 49-80-0307 (For use with electronic controlled

heat guns 8978, 8986-20 and 8988-20 only):
1. To install the air reflector nozzle to the heat gun, align the grooves on

the nozzle with the grooves on the heat gun nose.

2. Slide the nozzle onto the nose.
3. Adjust  heat,  distance  and  length  of  application  as  necessary.

To  reduce  the  risk  of  injury,  always  unplug  tool  before

attaching  or  removing  accessories  or  making  adjustments.

Use  only  specifically  recommended  accessories.  Others

may  be  hazardous.

WARNING!

To  reduce  the  risk  of  injury,  do  not  remove  accessory  tips

until  tool  has  cooled  to  room  temperature.

WARNING!

O

=

Off

 I

=

Low  Temperature

570° F (300° C)

I I

=

High Temperature

1000° F (540° C)

O

=

Off

 I

=

On

Summary of Contents for 8975

Page 1: ...DOR TO REDUCE THE RISK OF INJURY USER MUST READ AND UNDERSTAND OPERATOR S MANUAL AFIN DE R DUIRE LE RISQUE DE BLESSURES L UTILISATEUR DOIT LIRE ET BIEN COMPRENDRE LE MANUEL DE L UTILISATEUR PARA REDUC...

Page 2: ...the tool A wrench or a key that is left attached to a rotating part of the tool may result in personal injury 14 Do not overreach Keep proper footing and balance at all times Proper footing and balan...

Page 3: ...ssible move the workpiece outdoors If working indoors open windows and place an exhaust fan in a window Be sure the fan is moving air from inside to outside Proper ventilation will reduce the risk of...

Page 4: ...Do not modify the plug provided with the tool Never remove the grounding prong from the plug Do not use the tool if the cord or plug is damaged If damaged have it repaired by a MILWAUKEE service facil...

Page 5: ...No 8977 4 9 Cat No 8978 1 Accessory attachment area 2 Nozzle 3 Front cover 4 Nameplate 5 Heat adjustment knob 6 Intake vents 7 On off switch 8 Handle 9 Support base Cat No 8978 2 3 1 4 5 6 7 8 9 3 4...

Page 6: ...Slit and Cutting Nozzles The slit nozzle Cat No 49 80 0308 is used for lap welding The cutting nozzle Cat No 49 80 0309 is used as a heated cutting edge NOTE The reduction nozzle Cat No 49 80 0305 is...

Page 7: ...switch position Air Flow at Maximum Temperature Setting 7 CFM 8 8 CFM 16 CFM Cubic feet per minute Using the Airflow Control Switch Fig 5 Cat No 8986 20 8988 20 Cat No 8986 20 8988 20 have three airfl...

Page 8: ...m cutting nozzle first attach reduction nozzle Cat No 49 80 0305 to the heat gun See Installing Reduction Nozzles Attach the styrofoam nozzle to the reduction nozzle 2 To cut styrofoam use a low to me...

Page 9: ...o the nearest service center WARNING To reduce the risk of injury always unplug your tool before performing any maintenance Never disassemble the tool or try to do any rewiring on the tool s electrica...

Page 10: ...plexiglass soldering and directing heat into corners Reduction Nozzle Cat No 49 80 0297 Reduction nozzles intensify the application of heat in a specific area This nozzle may be used for soldering Sol...

Page 11: ...es 14 Ne vous penchez pas trop en avant Maintenez un bon appui et restez en quilibre en tout temps Un bonne stabilit vous permet de mieux r agir une situation inattendue 15 Utilisez des accessoires de...

Page 12: ...ou dans un environnement explosif fum es gaz ou poussi res la chaleur d gag e par le pistolet d caper pourrait enflammer la poussi re ou les fum es D barrassez le lieu de travail des d bris qui pourr...

Page 13: ...ous en servir Tenez votre cordon de rallonge l cart des objets ranchants des sources de grande chaleur et des endroits humides ou mouill s MISE LA TERRE CORDONSDERALLONGE Bas sur sur une chute de volt...

Page 14: ...8977 4 9 No de cat 8978 1 Aire de fixation des accessoires 2 Bec 3 Recouvrement 4 Fiche signal tique 5 Boutonde r lage de chaler 6 vents 7 Interrupteur on off 8 Poign e 9 Support No de cat 8978 2 3 1...

Page 15: ...8986 20 et 8988 20 1 Pour installer le r ducteur de d bit sur le pistolet d caper alignez les rainures internes du manchon du r ducteur sur les rainures du bec de l outil et glissez le en place 2 Glis...

Page 16: ...0 C 1000 F O Arr t I En marche Fig 4 Commande d intensit de chaleur Indicateur de temp rature Cat No 89786 20 et 8988 20 Fig 4 Ces pistolets d caper sont pourvus d une commande d intensit de chaleur v...

Page 17: ...aplatie du bout du pistolet No 8978 sert d appui Lorsque vous le placez en position renvers e sur le bout plat assurez vous que la position du cordon ne le fasse pas basculer Fig 5 Commande de d bit d...

Page 18: ...idements N B Il est normal qu une fum e l g re et de faibles odeurs se d gagent du mat riau Il n y aura pas de danger pourvu que la ventilation de votre lieu de travail soit ad quate Coupez la vitesse...

Page 19: ...e domestique qui en contiennent pourraient d t riorer le plastique et l isolation des pi ces Ne laissez jamais de solvants inflammables ou combustibles aupr s des outils R parations Si votre outil est...

Page 20: ...it No de cat 49 80 0297 Sert intensifier la chaleur des endroits sp cifiques Ce bec peut aussi faire des soudures Bec r flecteur souder No de cat 49 80 0307 L accessoire id al pour souder les joints d...

Page 21: ...ice ropa adecuada No use ropa suelta o joyas Mantenga el cabello largo ropa y guantes alejados de las partes m viles 12 Evite los arranques accidentales Verifique que el interruptor est apagado antes...

Page 22: ...mientras se enfr a para evitar la ignici n de materiales inflamables 7 No corte el flujo de aire colocando la boquilla demasiado cerca a la pieza de trabajo Mantenga las rendijas de entrada limpias y...

Page 23: ...e of Safety and Health NIOSH o United States Bureau of Mines Estas m scaras y filtros reemplazables est n disponibles en las principales ferreter as Aseg rese de que la m scara sea del tama o apropiad...

Page 24: ...e puesta a tierra proporciona un trayecto de baja resistencia para desviar la corriente el ctrica de la trayectoria del usuario reduciendo de este modo el riesgo de descarga el ctrica La clavija de co...

Page 25: ...ssories 2 Boquilla 3 Cubierta frontal 4 Place de especificationes 5 Bot n para ajustar el calor 6 Respiradero de admisi n 7 Interrupor de corriente 8 Empu adura 9 Base de soporte Cat No 8978 2 3 1 4 5...

Page 26: ...siempre desenchufe la herramienta antes de conectar o retirar los accesorios y hacer ajustes Use s lo los accesorios recomendados espec ficamente El uso de otros accesorios puede peligroso Instalaci n...

Page 27: ...e flujo de aire y temperatura Para reducir el riesgo de lesiones use siempre lentes de seguridad o anteojos con protectores laterales ADVERTENCIA Fig 3 Bot n para ajustar el calor Interruptor de corri...

Page 28: ...Nos 8975 y 8977 cuentan con una base de soporte que permite colocar la pistola en posici n erguida sobre una mesa de trabajo para que pueda usted tener las dos manos libres Cuando utilice los modelos...

Page 29: ...desea cortar Soldadura Fig 7 1 Acople la boquilla reflectora de soldadura o la boquilla de enganche a la pistola de calor 2 Quite las rebabas de la tuber a y de la junta con papel de lija o lana de ac...

Page 30: ...ienta limpias secas y libres de aceite y grasa Use s lo jab n neutro y un trapo h medo para limpiar su herramienta ya que algunas substancias y disolventes limpiadores pueden ocasionar da os a materia...

Page 31: ...espec fica Esta boquilla se puede usar para soldar Boquilla reductora Cat No 49 80 0306 Las boquillas reductoras intensifican la aplicaci n de calor en un rea espec fica Esta boquilla se usa en aplic...

Page 32: ...729 3878 fax 1 800 638 9582 email metproductsupport milwaukeetool com Monday Friday 8 00 AM 4 30 PM Central Time CANADA Service MILWAUKEE MEXICO Servicios de MILWAUKEE Milwaukee Electric Tool Blvd Ab...

Reviews: