Cat. No. 8986-20 and 8988-20 (Fig. 4)

These  heat  guns  have  a  variable  temperature  control  switch,  which

allows  the  user  to  adjust  the  temperature  for  specific  applications.

The electronic control system regulates the temperature within the tool’s

heating element. Unlike non-electronic heat guns, 

MILWAUKEE’s

 elec-

tronic  heat  gun  will  maintain  the  same  temperature  even  when  the  air

flow  is  decreased  or  restricted  with  the  use  of  accessory  nozzles.
Cat. No. 8978 is a variable temperature heat gun with a range between

200° F and 1100° F (93° C to 593° C). The heat adjustment knob is a dial

with  numbers  1  through  6  on  it  as  shown.  The  lower  numbers  corre-

spond to cooler temperatures and higher numbers correspond to warmer

temperatures. To adjust temperature, simply turn the dial to the left or the

right.

Airflow/Temperature Settings (8986-20 & 8988-20)

Airflow

Control

Switch

Setting

Position I

Position II

Position III

Airflow

 Fan

Speed

High

L o w

High

Minimum

  Temperature

Setting

90°F

90°F

90°F

Maximum

  Temperature

Setting

90°F

1100°F

1100°F

Fig. 4

Temperature

control  switch

Temperature  display

The  electronic  temperature  control  system  regulates  the  temperature

within  the  tool's  heating  element.  Unlike  non-electronic  heat  guns,

MILWAUKEE's

 electronic heat gun will maintain the same temperature

even  when  the  air  flow  is  decreased  or  restricted  with  the  use  of

accessory  nozzles.  Refer  to  the  airflow/temperature  chart  for  various

airflow  and  temperature  settings.
On  Cat.  No.  8988-20,  a  temperature  display  shows  the  heat  gun

temperature  setting.
1. Slide  the  airflow  control  switch  (blue  switch)  to  Position  II  or  III  to

operate  the  temperature  control  switch.

2. To adjust the temperature, slide the temperature control switch (red

switch)  to  the  desired  position.

When the temperature control switch is set to the desired position on the

8988-20, the temperature for that position will show on the temperature

display. After  3  seconds,  the  temperature  display  will  show  the  heat

gun’s actual temperature. The temperature display will continue to show

the actual temperature as the heat gun adjusts to the desired tempera-

ture  set  by  the  temperature  control  switch  position.

Air  Flow  at

Maximum

  Temperature

Setting

7 CFM*

8.8 CFM

16 CFM

* Cubic feet per minute

Using  the  Airflow  Control  Switch  (Fig.  5)

(Cat. No. 8986-20 & 8988-20)

Cat.  No.  8986-20  &  8988-20  have  three  airflow  settings:  high  without

heat, low with heat and high with heat. Refer to the airflow/temperature

chart  for  various  airflow  and  temperature  settings.

1. For  high  airflow  without  heat,  slide  the  airflow  control  switch  (blue

switch) to Position I.

NOTE:

 The temperature control switch (red switch) will not operate

in this position.

2. For  low  airflow  with  heat,  slide  the  airflow  control  switch  (blue

switch) to Position II. The temperature may be adjusted from 90°F to

1100°F  using  the  temperature  control  switch  (red  switch). The  air-

flow  will  automatically  increase  as  the  temperature  increases.

3. For  high  airflow  with  heat,  slide  the  airflow  control  switch  (blue

switch) to Position III. The temperature may be adjusted from 90°F to

1100°F  using  the  temperature  control  switch  (red  switch). The  air-

flow  will  automatically  increase  as  the  temperature  increases.

4. To turn the heat gun off, slide the airflow control switch (blue switch)

to Position 0.

Selecting  Temperature

The  proper  amount  of  heat  for  each  application  depends  on  the

temperature  range  selected,  distance  between  the  nozzle  and  work-

piece,  and  the  length  of  time  heat  is  applied.  Experiment  with  scrap

materials  and  start  with  lowest  temperature  range.  Be  cautious  when

working until the proper combination of heat, distance and time of appli-

cation has been obtained. Use a back and forth motion when applying

heat  unless  concentrated  heat  is  desirable.

Fig. 5

Airflow

control  switch

Support  Stand  (Cat.  Nos.  8975  and  8977)

Cat.  Nos.  8975  and  8977  have  a  support  stand,  which  allows  you  to

position the heat gun upright on a workbench, leaving both hands free

for  your  application.  When  using  Cat.  Nos.  8975  and  8977  on  a  work-

bench,  always  place  tool  on  a  flat  surface  and  snap  the  support  stand

into the notched position. Place the cord so the heat gun won’t tip. The

rear vent openings are designed to allow air flow even when the tool is

resting  on  the  end  cap,  but  it  is  important  not  to  cover  the  vents  with

foreign  materials  such  as  clothing  or  rags.  Cat.  No.  8978  has  a  flat

bottom  surface  that  acts  as  a  support  stand.  Rest  the  tool  on  the  flat

surface, making sure to place the cord so the heat gun won’t tip.

Summary of Contents for 8975

Page 1: ...DOR TO REDUCE THE RISK OF INJURY USER MUST READ AND UNDERSTAND OPERATOR S MANUAL AFIN DE R DUIRE LE RISQUE DE BLESSURES L UTILISATEUR DOIT LIRE ET BIEN COMPRENDRE LE MANUEL DE L UTILISATEUR PARA REDUC...

Page 2: ...the tool A wrench or a key that is left attached to a rotating part of the tool may result in personal injury 14 Do not overreach Keep proper footing and balance at all times Proper footing and balan...

Page 3: ...ssible move the workpiece outdoors If working indoors open windows and place an exhaust fan in a window Be sure the fan is moving air from inside to outside Proper ventilation will reduce the risk of...

Page 4: ...Do not modify the plug provided with the tool Never remove the grounding prong from the plug Do not use the tool if the cord or plug is damaged If damaged have it repaired by a MILWAUKEE service facil...

Page 5: ...No 8977 4 9 Cat No 8978 1 Accessory attachment area 2 Nozzle 3 Front cover 4 Nameplate 5 Heat adjustment knob 6 Intake vents 7 On off switch 8 Handle 9 Support base Cat No 8978 2 3 1 4 5 6 7 8 9 3 4...

Page 6: ...Slit and Cutting Nozzles The slit nozzle Cat No 49 80 0308 is used for lap welding The cutting nozzle Cat No 49 80 0309 is used as a heated cutting edge NOTE The reduction nozzle Cat No 49 80 0305 is...

Page 7: ...switch position Air Flow at Maximum Temperature Setting 7 CFM 8 8 CFM 16 CFM Cubic feet per minute Using the Airflow Control Switch Fig 5 Cat No 8986 20 8988 20 Cat No 8986 20 8988 20 have three airfl...

Page 8: ...m cutting nozzle first attach reduction nozzle Cat No 49 80 0305 to the heat gun See Installing Reduction Nozzles Attach the styrofoam nozzle to the reduction nozzle 2 To cut styrofoam use a low to me...

Page 9: ...o the nearest service center WARNING To reduce the risk of injury always unplug your tool before performing any maintenance Never disassemble the tool or try to do any rewiring on the tool s electrica...

Page 10: ...plexiglass soldering and directing heat into corners Reduction Nozzle Cat No 49 80 0297 Reduction nozzles intensify the application of heat in a specific area This nozzle may be used for soldering Sol...

Page 11: ...es 14 Ne vous penchez pas trop en avant Maintenez un bon appui et restez en quilibre en tout temps Un bonne stabilit vous permet de mieux r agir une situation inattendue 15 Utilisez des accessoires de...

Page 12: ...ou dans un environnement explosif fum es gaz ou poussi res la chaleur d gag e par le pistolet d caper pourrait enflammer la poussi re ou les fum es D barrassez le lieu de travail des d bris qui pourr...

Page 13: ...ous en servir Tenez votre cordon de rallonge l cart des objets ranchants des sources de grande chaleur et des endroits humides ou mouill s MISE LA TERRE CORDONSDERALLONGE Bas sur sur une chute de volt...

Page 14: ...8977 4 9 No de cat 8978 1 Aire de fixation des accessoires 2 Bec 3 Recouvrement 4 Fiche signal tique 5 Boutonde r lage de chaler 6 vents 7 Interrupteur on off 8 Poign e 9 Support No de cat 8978 2 3 1...

Page 15: ...8986 20 et 8988 20 1 Pour installer le r ducteur de d bit sur le pistolet d caper alignez les rainures internes du manchon du r ducteur sur les rainures du bec de l outil et glissez le en place 2 Glis...

Page 16: ...0 C 1000 F O Arr t I En marche Fig 4 Commande d intensit de chaleur Indicateur de temp rature Cat No 89786 20 et 8988 20 Fig 4 Ces pistolets d caper sont pourvus d une commande d intensit de chaleur v...

Page 17: ...aplatie du bout du pistolet No 8978 sert d appui Lorsque vous le placez en position renvers e sur le bout plat assurez vous que la position du cordon ne le fasse pas basculer Fig 5 Commande de d bit d...

Page 18: ...idements N B Il est normal qu une fum e l g re et de faibles odeurs se d gagent du mat riau Il n y aura pas de danger pourvu que la ventilation de votre lieu de travail soit ad quate Coupez la vitesse...

Page 19: ...e domestique qui en contiennent pourraient d t riorer le plastique et l isolation des pi ces Ne laissez jamais de solvants inflammables ou combustibles aupr s des outils R parations Si votre outil est...

Page 20: ...it No de cat 49 80 0297 Sert intensifier la chaleur des endroits sp cifiques Ce bec peut aussi faire des soudures Bec r flecteur souder No de cat 49 80 0307 L accessoire id al pour souder les joints d...

Page 21: ...ice ropa adecuada No use ropa suelta o joyas Mantenga el cabello largo ropa y guantes alejados de las partes m viles 12 Evite los arranques accidentales Verifique que el interruptor est apagado antes...

Page 22: ...mientras se enfr a para evitar la ignici n de materiales inflamables 7 No corte el flujo de aire colocando la boquilla demasiado cerca a la pieza de trabajo Mantenga las rendijas de entrada limpias y...

Page 23: ...e of Safety and Health NIOSH o United States Bureau of Mines Estas m scaras y filtros reemplazables est n disponibles en las principales ferreter as Aseg rese de que la m scara sea del tama o apropiad...

Page 24: ...e puesta a tierra proporciona un trayecto de baja resistencia para desviar la corriente el ctrica de la trayectoria del usuario reduciendo de este modo el riesgo de descarga el ctrica La clavija de co...

Page 25: ...ssories 2 Boquilla 3 Cubierta frontal 4 Place de especificationes 5 Bot n para ajustar el calor 6 Respiradero de admisi n 7 Interrupor de corriente 8 Empu adura 9 Base de soporte Cat No 8978 2 3 1 4 5...

Page 26: ...siempre desenchufe la herramienta antes de conectar o retirar los accesorios y hacer ajustes Use s lo los accesorios recomendados espec ficamente El uso de otros accesorios puede peligroso Instalaci n...

Page 27: ...e flujo de aire y temperatura Para reducir el riesgo de lesiones use siempre lentes de seguridad o anteojos con protectores laterales ADVERTENCIA Fig 3 Bot n para ajustar el calor Interruptor de corri...

Page 28: ...Nos 8975 y 8977 cuentan con una base de soporte que permite colocar la pistola en posici n erguida sobre una mesa de trabajo para que pueda usted tener las dos manos libres Cuando utilice los modelos...

Page 29: ...desea cortar Soldadura Fig 7 1 Acople la boquilla reflectora de soldadura o la boquilla de enganche a la pistola de calor 2 Quite las rebabas de la tuber a y de la junta con papel de lija o lana de ac...

Page 30: ...ienta limpias secas y libres de aceite y grasa Use s lo jab n neutro y un trapo h medo para limpiar su herramienta ya que algunas substancias y disolventes limpiadores pueden ocasionar da os a materia...

Page 31: ...espec fica Esta boquilla se puede usar para soldar Boquilla reductora Cat No 49 80 0306 Las boquillas reductoras intensifican la aplicaci n de calor en un rea espec fica Esta boquilla se usa en aplic...

Page 32: ...729 3878 fax 1 800 638 9582 email metproductsupport milwaukeetool com Monday Friday 8 00 AM 4 30 PM Central Time CANADA Service MILWAUKEE MEXICO Servicios de MILWAUKEE Milwaukee Electric Tool Blvd Ab...

Reviews: