Grounded  tools  require  a  three  wire  extension  cord.  Double  insulated

tools can use either a two or three wire extension cord. As the distance

from the supply outlet increases, you must use a heavier gauge exten-

sion cord. Using extension cords with inadequately sized wire causes a

serious  drop  in  voltage,  resulting  in  loss  of  power  and  possible  tool

damage.  Refer  to  the  table  shown  to  determine  the  required  minimum

wire  size.
The smaller the gauge number of the wire, the greater the capacity of the

cord. For example, a 14 gauge cord can carry a higher current than a 16

gauge cord. When using more than one extension cord to make up the

total length, be sure each cord contains at least the minimum wire size

required. If you are using one extension cord for more than one tool, add

the nameplate amperes and use the sum to determine the required mini-

mum wire size.

Guidelines  for  Using  Extension  Cords

•

If  you  are  using  an  extension  cord  outdoors,  be  sure  it  is  marked

with the suffix “W-A” (“W” in Canada) to indicate that it is acceptable

for  outdoor  use.

•

Be sure your extension cord is properly wired and in good electrical

condition.  Always  replace  a  damaged  extension  cord  or  have  it

repaired by a qualified person before using it.

•

Protect  your  extension  cords  from  sharp  objects,  excessive  heat

and damp  or  wet  areas.

GROUNDING

EXTENSION CORDS

Grounded  Tools:

Tools  with  Three  Prong  Plugs

Tools  marked  “Grounding  Required”

have  a  three  wire  cord  and  three

prong grounding plug. The plug must

be connected to a properly grounded

outlet (See Figure A). If the tool should

electrically  malfunction  or  break

down,  grounding  provides  a  low  re-

sistance  path  to  carry  electricity

away from the user, reducing the risk

of  electric  shock.

Improperly  connecting  the  grounding  wire  can  result  in  the

risk of electric shock. Check with a qualified electrician if you

are  in  doubt  as  to  whether  the  outlet  is  properly  grounded.

Do  not  modify  the  plug  provided  with  the  tool.  Never  remove

the grounding prong from the plug. Do not use the tool if the

cord  or  plug  is  damaged.  If  damaged,  have  it  repaired  by  a

MILWAUKEE

  service  facility  before  use.  If  the  plug  will  not  fit

the  outlet,  have  a  proper  outlet  installed  by  a  qualified

electrician.

Nameplate

Amperes

0 - 5

5.1 - 8

8.1 - 12

12.1 - 15

15.1 - 20

Extension Cord Length

25'

16

16

14

12

10

75'

16

14

12

10

10

100'

14

12

10

10

--

150'

12

10

--

--

--

200'

12

--

--

--

--

Recommended  Minimum  Wire  Gauge

for  Extension  Cords*

* Based on limiting the line voltage drop to five

volts at 150% of the rated amperes.

50'

16

16

14

12

10

READ AND SAVE ALL INSTRUCTIONS

FOR FUTURE USE.

The  grounding  prong  in  the  plug  is  connected  through  the  green  wire

inside the cord to the grounding system in the tool. The green wire in the

cord must be the only wire connected to the tool's grounding system and

must never be attached to an electrically “live” terminal.
Your tool must be plugged into an appropriate outlet, properly installed

and  grounded  in  accordance  with  all  codes  and  ordinances.  The  plug

and outlet should look like those in Figure A.

Double  Insulated  Tools:

Tools  with  Two  Prong  Plugs

Tools marked “Double Insulated” do

not  require  grounding.  They  have  a

special  double  insulation  system

which  satisfies  OSHA  requirements

and  complies  with  the  applicable

standards  of  Underwriters  Labora-

tories,  Inc.,  the  Canadian  Standard

Association and the National Electri-

cal Code. Double Insulated tools may

be used in either of the 120 volt out-

lets shown in Figures B and C.

WARNING!

Fig. A

Fig. B

Fig. C

Specifications

Cat.

No.

8975

8977

8978

8986-20

8988-20

Volts

AC

120

120

120

120

120

Max.

Amps

11.6

11.6

12.5

12.5

12.5

Max.

Watts

1400

1400

1500

1500

1500

Temperature

570° F / 1000° F

(300°C / 540°C)

140° F / 1040° F

(60°C / 560°C)

200° F / 1100° F

(93°C / 593°C)

90°F / 1100°F

(32°C - 593°C)

90°F / 1100°F

(32°C - 593°C)

Airflow

CFM*

14.8

14.8

14.8

7-16

7-16

          * Cubic feet per minute

Double insulated

Symbology

Volts  alternating  current

Amps

Canadian  Standards Association

Watts

Underwriters  Laboratories,  Inc.

Underwriters  Laboratories,  Inc.

(UL Listed to U.S. and Canadian

safety  standards)

Summary of Contents for 8975

Page 1: ...DOR TO REDUCE THE RISK OF INJURY USER MUST READ AND UNDERSTAND OPERATOR S MANUAL AFIN DE R DUIRE LE RISQUE DE BLESSURES L UTILISATEUR DOIT LIRE ET BIEN COMPRENDRE LE MANUEL DE L UTILISATEUR PARA REDUC...

Page 2: ...the tool A wrench or a key that is left attached to a rotating part of the tool may result in personal injury 14 Do not overreach Keep proper footing and balance at all times Proper footing and balan...

Page 3: ...ssible move the workpiece outdoors If working indoors open windows and place an exhaust fan in a window Be sure the fan is moving air from inside to outside Proper ventilation will reduce the risk of...

Page 4: ...Do not modify the plug provided with the tool Never remove the grounding prong from the plug Do not use the tool if the cord or plug is damaged If damaged have it repaired by a MILWAUKEE service facil...

Page 5: ...No 8977 4 9 Cat No 8978 1 Accessory attachment area 2 Nozzle 3 Front cover 4 Nameplate 5 Heat adjustment knob 6 Intake vents 7 On off switch 8 Handle 9 Support base Cat No 8978 2 3 1 4 5 6 7 8 9 3 4...

Page 6: ...Slit and Cutting Nozzles The slit nozzle Cat No 49 80 0308 is used for lap welding The cutting nozzle Cat No 49 80 0309 is used as a heated cutting edge NOTE The reduction nozzle Cat No 49 80 0305 is...

Page 7: ...switch position Air Flow at Maximum Temperature Setting 7 CFM 8 8 CFM 16 CFM Cubic feet per minute Using the Airflow Control Switch Fig 5 Cat No 8986 20 8988 20 Cat No 8986 20 8988 20 have three airfl...

Page 8: ...m cutting nozzle first attach reduction nozzle Cat No 49 80 0305 to the heat gun See Installing Reduction Nozzles Attach the styrofoam nozzle to the reduction nozzle 2 To cut styrofoam use a low to me...

Page 9: ...o the nearest service center WARNING To reduce the risk of injury always unplug your tool before performing any maintenance Never disassemble the tool or try to do any rewiring on the tool s electrica...

Page 10: ...plexiglass soldering and directing heat into corners Reduction Nozzle Cat No 49 80 0297 Reduction nozzles intensify the application of heat in a specific area This nozzle may be used for soldering Sol...

Page 11: ...es 14 Ne vous penchez pas trop en avant Maintenez un bon appui et restez en quilibre en tout temps Un bonne stabilit vous permet de mieux r agir une situation inattendue 15 Utilisez des accessoires de...

Page 12: ...ou dans un environnement explosif fum es gaz ou poussi res la chaleur d gag e par le pistolet d caper pourrait enflammer la poussi re ou les fum es D barrassez le lieu de travail des d bris qui pourr...

Page 13: ...ous en servir Tenez votre cordon de rallonge l cart des objets ranchants des sources de grande chaleur et des endroits humides ou mouill s MISE LA TERRE CORDONSDERALLONGE Bas sur sur une chute de volt...

Page 14: ...8977 4 9 No de cat 8978 1 Aire de fixation des accessoires 2 Bec 3 Recouvrement 4 Fiche signal tique 5 Boutonde r lage de chaler 6 vents 7 Interrupteur on off 8 Poign e 9 Support No de cat 8978 2 3 1...

Page 15: ...8986 20 et 8988 20 1 Pour installer le r ducteur de d bit sur le pistolet d caper alignez les rainures internes du manchon du r ducteur sur les rainures du bec de l outil et glissez le en place 2 Glis...

Page 16: ...0 C 1000 F O Arr t I En marche Fig 4 Commande d intensit de chaleur Indicateur de temp rature Cat No 89786 20 et 8988 20 Fig 4 Ces pistolets d caper sont pourvus d une commande d intensit de chaleur v...

Page 17: ...aplatie du bout du pistolet No 8978 sert d appui Lorsque vous le placez en position renvers e sur le bout plat assurez vous que la position du cordon ne le fasse pas basculer Fig 5 Commande de d bit d...

Page 18: ...idements N B Il est normal qu une fum e l g re et de faibles odeurs se d gagent du mat riau Il n y aura pas de danger pourvu que la ventilation de votre lieu de travail soit ad quate Coupez la vitesse...

Page 19: ...e domestique qui en contiennent pourraient d t riorer le plastique et l isolation des pi ces Ne laissez jamais de solvants inflammables ou combustibles aupr s des outils R parations Si votre outil est...

Page 20: ...it No de cat 49 80 0297 Sert intensifier la chaleur des endroits sp cifiques Ce bec peut aussi faire des soudures Bec r flecteur souder No de cat 49 80 0307 L accessoire id al pour souder les joints d...

Page 21: ...ice ropa adecuada No use ropa suelta o joyas Mantenga el cabello largo ropa y guantes alejados de las partes m viles 12 Evite los arranques accidentales Verifique que el interruptor est apagado antes...

Page 22: ...mientras se enfr a para evitar la ignici n de materiales inflamables 7 No corte el flujo de aire colocando la boquilla demasiado cerca a la pieza de trabajo Mantenga las rendijas de entrada limpias y...

Page 23: ...e of Safety and Health NIOSH o United States Bureau of Mines Estas m scaras y filtros reemplazables est n disponibles en las principales ferreter as Aseg rese de que la m scara sea del tama o apropiad...

Page 24: ...e puesta a tierra proporciona un trayecto de baja resistencia para desviar la corriente el ctrica de la trayectoria del usuario reduciendo de este modo el riesgo de descarga el ctrica La clavija de co...

Page 25: ...ssories 2 Boquilla 3 Cubierta frontal 4 Place de especificationes 5 Bot n para ajustar el calor 6 Respiradero de admisi n 7 Interrupor de corriente 8 Empu adura 9 Base de soporte Cat No 8978 2 3 1 4 5...

Page 26: ...siempre desenchufe la herramienta antes de conectar o retirar los accesorios y hacer ajustes Use s lo los accesorios recomendados espec ficamente El uso de otros accesorios puede peligroso Instalaci n...

Page 27: ...e flujo de aire y temperatura Para reducir el riesgo de lesiones use siempre lentes de seguridad o anteojos con protectores laterales ADVERTENCIA Fig 3 Bot n para ajustar el calor Interruptor de corri...

Page 28: ...Nos 8975 y 8977 cuentan con una base de soporte que permite colocar la pistola en posici n erguida sobre una mesa de trabajo para que pueda usted tener las dos manos libres Cuando utilice los modelos...

Page 29: ...desea cortar Soldadura Fig 7 1 Acople la boquilla reflectora de soldadura o la boquilla de enganche a la pistola de calor 2 Quite las rebabas de la tuber a y de la junta con papel de lija o lana de ac...

Page 30: ...ienta limpias secas y libres de aceite y grasa Use s lo jab n neutro y un trapo h medo para limpiar su herramienta ya que algunas substancias y disolventes limpiadores pueden ocasionar da os a materia...

Page 31: ...espec fica Esta boquilla se puede usar para soldar Boquilla reductora Cat No 49 80 0306 Las boquillas reductoras intensifican la aplicaci n de calor en un rea espec fica Esta boquilla se usa en aplic...

Page 32: ...729 3878 fax 1 800 638 9582 email metproductsupport milwaukeetool com Monday Friday 8 00 AM 4 30 PM Central Time CANADA Service MILWAUKEE MEXICO Servicios de MILWAUKEE Milwaukee Electric Tool Blvd Ab...

Reviews: