Model: FWAP to be used with any CS  model heater

Any of the following models may be replaced using the FW conversion kit:

FW051, RW051, FW052, RW052, FW071, RW071, FW751, RW071, FW752, RW752
FW072, RW072, FW101, RW101, FW102, RW102, FW121, RW121, FW122, RW122
FW151, RW151, FW152, RW152, FW202, RW202, FW252, RW252, FW302, RW302
*The above models may be controlled by either a built-in thermostat or a wall mount thermostat.

General Safety Information

PARTS INClUDED:

3 Screws

2 Spring Nuts

2 Lead Wires

1 Replacement Grill Label

2 Mounting Screws

1 Conversion Plate

3 Lock Tooth Washers

1 Instruction Guide

TOOlS REqUIRED:

Phillips Screwdriver

Straight Screwdriver

WARNING!

Turn the electrical power off at the

electrical  panel  board  (circuit

breaker  or  fuse  box)  and  lock  or

tag  the  panel  board  door  to 

prevent someone from turning on

power  while  you  are  working  on

the heater. Failure to do so could

result  in  serious  electrical  shock,

burns, or possible death.

1.

WARNING

Risk of fire or property damage.

DO NOT 

replace your heater with a higher wattage assembly.

Replace  your  heater  with  the  same  voltage  and  wattage  that

was  originally  installed.  Replacing  it  with  a  higher  wattage

heater  could  result  in  an  overloaded  electrical  circuit  in  your

home, which could result in a fire and serious property damage.

Replacing with a lower wattage heater may cause insufficient

heat and result in increased energy costs.

2.

All electrical work and materials must comply with the National

Electric Code (NEC), the Occupational Safety and Health Act

(OSHA), and all state and local codes.

3.

When  installing  the  heater  conversion  kit,  be  certain  the  FW

heater being replaced was wired correctly to all electrical codes

and the supply wiring is the correct size and in good condition.

If not, it must be replaced before proceeding.

4.

If  you  need  to  install  a  new  circuit  or  need  additional  wiring

information, consult a qualified electrician.

5.

Protect electrical supply from kinks, sharp objects, oil, grease,

hot surfaces or chemicals.

Features & Benefits

Converts discontinued FW Series wall can
to newer Com-Pak or Com-Pak Max

UL Listed for installation of Com-Pak
model into FW wall can

No sheetrock construction necessary -
saves time and money

Vertical or horizontal installation

If you are uncomfortable working with electrical appliances, unable to follow these guidelines, 

or do not have the necessary equipment, consult a licensed electrician.

vertical installation shown

1

SAVE THESE INSTRUCTIONS

cadetheat.com    Tel: 360-693-2505    P.O. Box 1675    Vancouver, WA    98668-1675

©2014 Cadet     Printed in U.S.A.     12/14    #720027