OM-2226 Page 41
B.
Selecting GEN
1
Encoder Control
2
Amps Meter
3
Amperage Switch Pad
If [GEn]
is selected and displayed
on the amps meter, the TIG starting
parameters for a .094 tungsten are
the default: Start Amperage = 60 A,
Start Time = 1 ms, Start Slope Time
= 40 ms, Preset Minimum Amps =
3 A. These parameters can be
manually changed by pressing the
Amperage switch pad to step
through each adjustable paramet-
er. To change parameters, see Sec-
tions C, D, E, and F.
1
GEn
2
Current (A)
Start Time
Start Slope Time
Preset Amperage Minimum
Start
Amperage
1 ms
60
Amps
40 ms
3 Amps
GEN Default DC TIG Start Parameter Relationships