OM-2226 Page 39
SECTION 6
−
ADVANCED FUNCTIONS
6-1. Accessing Advanced Functions
3
1
2
1
Amperage Switch Pad
2
Adjust
3
Encoder Control
To access the advanced functions, press
and hold the Amperage (A) switch pad and
then press the Adjust switch pad. To scroll
through the advanced functions, press and
release the Adjust switch pad. Use the En-
coder control to change parameters for
each function.
Advanced Functions:
•
Programmable TIG Start Parameters
(see Section 6-2)
−
Allows you to set
amps, time, and polarity to customize arc
starts for different tungstens.
•
Output Remote Hold And Trigger Func-
tions (see Section 6-3)
−
For reconfigur-
ing RMT 2T Hold for 3T, 4T Momentary,
or Mini Logic
•
Preflow Time (see Section 6-4)
−
Sets the
gas flow time before TIG arc starts.
•
Stick OCV Selection (see Section 6-5)
−
Allows you to select either low or normal
OCV (open circuit voltage).
•
Stick Stuck Check Selection (See Sec-
tion 6-6)
−
With Stick Stuck Check on and
the welding electrode (rod) stuck, output
is turned off in an attempt to save the rod
for reuse.
•
Lockout Functions (see Section 6-7)
−
Allows you to turn the lockout function on
and off and adjust the lockout levels.
•
Meter Displays (see Section 6-8)
−
Al-
lows you to set meters to display weld
voltage and amperage, or blank meters
while pulse welding.
•
External Pulse Control (see Section 6-9)
−
Used for external pulse control when
external pulse control is desired.
To exit advanced functions, press and hold
the Amperage (A) switch pad and then
press the Adjust switch pad.
Summary of Contents for Maxstar 200 DX
Page 6: ...Notes...
Page 16: ...OM 2226 Page 10...
Page 65: ...OM 2226 Page 59 SECTION 8 ELECTRICAL DIAGRAMS Figure 8 1 Circuit Diagram 237 566 B...
Page 79: ...OM 2226 Page 73 Notes...
Page 89: ...OM 2226 Page 83 Notes...