OM-2226 Page 30
5-5. Voltmeter
1
Volt Meter
Displays output or open circuit volt-
age. If output is off, the voltmeter will
display a series of three dashes
(-
−−
). Open circuit voltage is dis-
played if power is on and output is
available.
1
5-6. Process Control
1
Process Control
Press switch pad until desired pro-
cess LED is illuminated:
TIG HF Impulse
- When selected,
a pulsed HF (non-contact) (see
Section 5-7) arc starting method is
activated. This method can be used
with either AC or DC TIG welding.
Make connections according to
Section 4-12.
TIG Lift-Arc
t
- When selected, is
an arc starting method in which the
electrode must come in contact
with the workpiece to initiate an arc
(see Section 5-7). This method can
be used with either AC or DC TIG
welding. Make connections ac-
cording to Section 4-12.
Stick (SMAW)
- This method can
be used with either AC or DC Stick
welding. Make connections ac-
cording to Section 4-13.
1