OM-2226 Page 37
ADJUST
*PREFLOW
POST FLOW
DIG
0.2 S
10.0 S
30%
0.0
−
25.0 Seconds
0.0
−
50.0 Seconds @ 0.2 Second Resolution
0
−
100 Percent
MAXSTAR:
*Tungsten
***Amperage
***Time
***Start Slope Time
***Preset Amperage Minimum
.094
60
1
40
3
GEN, .020, .040, .062, .094, .125
1
−
200 Amps
1
−
200 Milliseconds
0
−
250 Milliseconds
1
−
20 Amps
* Parameter adjusted using an Advanced Functions configuration only (see Section 6).
**
Parameter used with the automation option (LX models only).
***Parameter adjust using Tungsten GEN only.
5-14. Resetting Unit To Factory Default Settings (All Models)
1
Process Switch Pad
2
Output Switch Pad
3
Adjust Switch Pad
4
Power Switch
To reset all welding power source
functions to original factory settings,
lockout feature must be off (see Sec-
tion 6-7). Next turn power on, then
press the Process, Output, and Ad-
just switch pads before the software
version clears the meters, and hold
the switch pads until software ver-
sion clears the meters.
1
2
3
Rear Panel
4