OM-2226 Page 20
4-8. Remote 14 Receptacle Information
ST-802 541
A
J
B
K
I
C L N
H
D M
G
E
F
Socket*
Socket Information
15 VOLTS DC
OUTPUT
CONTACTOR
A
Contactor c15 volts DC.
B
Contact closure to A completes 15 volts DC
contactor control circuit and enables output.
REMOTE
OUTPUT
CONTROL
C
Output to remote control; 0 to +10 volts DC output
to remote control.
D
Remote control circuit common.
E
0 to +10 volts DC input command signal from
remote control.
A/V
AMPERAGE
VOLTAGE
F
Current feedback; +1 volt DC per 100 amperes.
H
Voltage feedback; +1 volt DC per 10 volts output.
GND
G
+15 volts DC GND
CHASSIS
K
Chassis common.
.
If a remote hand control, like the RHC-14, is connected to the Remote 14 receptacle, some current value above min. must be set on the remote
control before the Panel or Remote contactor is turned on. Failure to do so will cause current to be controlled by the panel control, and the remote
hand control will not function.
* The remaining sockets are not used.