OM-2226 Page 61
SECTION 10
−
SETUP GUIDES FOR (GTAW) TIG WELDING
207 690-A
This symbol indicates which functions should be active for stainless steel.
•
Turn power on (switch located on rear panel)
•
Press Process switch pad until TIG HF Impulse LED is lit
•
Press Output switch pad until RMT STD LED is lit
•
Press Adjust switch pad until Post Flow LED is lit
•
Turn Encoder control to set 8 seconds of Post Flow time
•
Press Amperage
A
switch pad until LED is lit
•
Turn Encoder control to set desired amperage (50 - 80 amps).
.
The ammeter displays the parameter for any of the following units of measure when they are active: amperage, time, percentage,
or frequency. The corresponding LED, located directly below the ammeter, will also light up. The ammeter also displays actual
amperage while welding.
Ammeter
10-1. DC - GTAW 16 Gauge Stainless Steel Set-Up
Encoder
Summary of Contents for Maxstar 200 DX
Page 6: ...Notes...
Page 16: ...OM 2226 Page 10...
Page 65: ...OM 2226 Page 59 SECTION 8 ELECTRICAL DIAGRAMS Figure 8 1 Circuit Diagram 237 566 B...