OM-2226 Page 40
6-2. Programmable TIG Start Parameters
A.
Tungsten Selection
2
tun
094
3
1
Amperage Switch Pad
2
Encoder Control
3
Amps Meter
Preset TIG Start Parameters
Use Encoder control to select a tungsten
size from the following: .020, .040, .062
(1/16 in.), .094 (3/32 in.), or .125 (1/8 in.)
(.094 is the default). When one of the listed
tungsten sizes is selected, the following
TIG starting parameters are preset: Am-
perage, Start Time, Start Slope Time, and
Preset Amperage Minimum. If it is neces-
sary or desired to manually set the TIG
starting parameters, turn the encoder until
[GEn]
is displayed on the amps meter (see
Section B).
Current (A)
Start Time
Start Slope
Time
Preset Amperage Minimum
Start
Amperage
1