OM-257 675 Page 104
C. General Purpose LEDs
D17
On
Gnd Cnt
−
Indicates ground error. Contact nearest factory Authorized Service Agent.
Off
Indicates no error
D25
On
OVR CNT
−
Indicates an error. Contact nearest factory Authorized Service Agent.
Off
Indicates no error
D26
On
OVR PWR
−
Indicates unit is operating at max input current. Contact nearest factory Authorized Service
Agent.
Off
Indicates no error
D28
— —
Future use
— —
D30
On
OVR TMP
−
Indicates unit is overheated. Turn unit off and allow to cool. If error continues, contact nearest
factory Authorized Service Agent.
Off
Indicates no error
D33
On
Contactor
−
Indicates unit is receiving a contactor On signal
Off
Indicates contactor on signal is not being received. Check input connections.
D43
On
ARM/O
−
Ind10 VDC is present, should flash at same rate as ARM AWAKE
Off
Ind10 VDC is not present
D44
On
E-Stop
−
Indicates E-Stop is not present
Off
Indicates E-Stop has been engaged, check external sources
D98
On
USB Host on
−
Indicates this function is operating properly
Off
Indicates USB error. Cycle unit power, if error is still present contact nearest factory Authorized Service
Agent
D101
On
Ind2.5 VDC is present
Off
Ind2.5 VDC is not present
D108
On
Ind25 VDC is present
Off
Ind25 VDC is not present
13-5. Network And Module Status LEDs
A.
Network Status LED
LED2 on the E Module board stack
Status
Diagnosis
Off
The board stack is not on-line with the network or there is no power applied to the board stack.
Green
The board stack is operating normally and the on-line connection is made with the network.
Flashing Green
The board stack is waiting for an on-line connection to be made with the network.
Red
The board stack has encountered a communication link failure with the network. Check DeviceNet cable connections. Replace
board stack if necessary.
B.
Module Status LED
LED1 on the E Module board stack
Status
Diagnosis
Off
There is no power applied to the board stack or the board stack software is not executing its functions.
Green
The board stack is operating normally.
Flashing Red
The board stack has encountered a recoverable fault. Wait or cycle power to clear fault.
Red
The board stack has encountered an unrecoverable fault.
Summary of Contents for Auto-Axcess E Digital
Page 6: ......
Page 16: ...OM 257 675 Page 10...
Page 18: ...OM 257 675 Page 12 Notes...
Page 22: ...OM 257 675 Page 16 Notes...
Page 26: ...OM 257 675 Page 20 Notes...
Page 30: ...OM 257 675 Page 24 Notes...
Page 37: ...General OM 257 675 Page 31 Notes...
Page 98: ...Safety OM 257 675 Page 92 Notes...
Page 115: ...Trouble OM 257 675 Page 109 Notes...
Page 121: ...Circuits OM 257 675 Page 115 257 679 A Part 2 Of 2...
Page 123: ...Circuits OM 257 675 Page 117 257 678 A Part 1 Of 2...
Page 125: ...Circuits OM 257 675 Page 119 257 678 A Part 2 Of 2...
Page 127: ...Circuits OM 257 675 Page 121 257 676 A Part 1 Of 2...
Page 129: ...Circuits OM 257 675 Page 123 257 676 A Part 2 Of 2...
Page 130: ...OM 257 675 Page 124 Figure 15 7 Circuit Diagram For Axcess E Digital Module...
Page 131: ...Circuits OM 257 675 Page 125 257 680 A...
Page 132: ...OM 257 675 Page 126 Figure 15 8 Circuit Diagram For Motor And Digital I O Interface...
Page 133: ...Circuits OM 257 675 Page 127 258 246 A...
Page 143: ...E450 Parts OM 257 675 Page 137 Notes...