Troubleshooting
4-16
SCM4000
Operator’s Guide/Tech Ref Manual
If your errors are 0.000e+00 to 1.000e-07, then your
link is good. Go to step 8.
If your errors are greater than 1.000e-07, you probably
have a problem with modulation modes being different
on the Modulator and Demodulator or the spectral
inversion is set incorrectly. Check the modulation
modes and spectral inversion settings, make the
necessary changes, and repeat from step 6.
If your errors are about equal to 1.000e-07, your
modulation modes are the same on the Modulator and
Demodulator, and the spectral inversion is set
correctly, check the SNR per
.
Make the necessary changes and repeat from step 6.
8.
Turn off PRBS on the Modulator.
Change PRBS State” on page 3-74
.
9.
Turn off PRBS on the Demodulator.
Change PRBS State” on page 3-112
.