Troubleshooting
4-5
SCM4000
Operator’s Guide/Tech Ref Manual
E26C
SMPTE PLL
SMPTE Phase Lock Loop - The
phase lock loop is having trouble
locking to the incoming signal.
This could happen if the SMPTE
signal has excessive jitter or if the
signal is non-conforming (i.e., off
frequency).
•
Verify that you have a clean
SMPTE stream.
•
Contact technical staff.
If problem persists, possible
hardware failure. Contact MRC
Technical Support.
E26D
RS232 LOS
Loss of Signal - The given
interface doesn’t recognize or
can’t lock to the given input signal.
•
Verify a valid signal is
connected.
•
Contact technical staff.
If problem persists, possible
hardware failure. Contact MRC
Technical Support.
E26E
RS485 LOS
Table 4-3: SCM4000 Demodulator Primary Error Codes
Error
Code
Error Message
Meaning
Suggested Operator Action
Suggested Technical Staff
Action
Status Errors
(Some part of System is reporting an abnormal condition.)
E240
Dem Ch1 OF
Channel 1 FIFO Overflow Fault
•
Verify the Demodulator has the
correct data rate for the given
channel.
•
Contact technical staff.
If problem persists, possible
hardware failure. Contact MRC
Technical Support.
E241
Dem Ch2 OF
Channel 2 FIFO Overflow Fault
E242
Dem Ch3 OF
Channel 3 FIFO Overflow Fault
E243
Dem Ch4 OF
Channel 4 FIFO Overflow Fault
E244
Dem Ch1 UF
Channel 1 FIFO Underflow Fault
E245
Dem Ch2 UF
Channel 2 FIFO Underflow Fault
E246
Dem Ch3 UF
Channel 3 FIFO Underflow Fault
E247
Dem Ch4 UF
Channel 4 FIFO Underflow Fault
Table 4-2: SCM4000 Modulator Primary Error Codes (Continued)
Error
Code
Error Message
Meaning
Suggested Operator Action
Suggested Technical Staff
Action
Summary of Contents for SCM4000
Page 2: ......
Page 14: ...Introduction 1 4 SCM4000 Operator s Guide This page intentionally left blank ...
Page 234: ...Repair 6 2 SCM4000 Technical Reference Manual This page intentionally left blank ...
Page 242: ...Theory of Operation 8 6 SCM4000 Technical Reference Manual This page intentionally left blank ...
Page 250: ...Glossary A 8 SCM4000 Operator s Guide Tech Ref Manual This page intentionally left blank ...
Page 274: ...Index 8 SCM4000 Technical Reference Manual This page intentionally left blank ...