9.3.3. Manual Adjusting of Sensor Current and Switching Threshold
Manual adjusting of the Sync sensor current and switching threshold allows
the processing of materials with high contrast proof points within the label,
which would otherwise be falsely measured by the system. *)
The panel functions Sensor Test and Sync Sens Level serve to adjust the
Sync sensors (Reflex sensor and Gap sensor) to special media (material to
print on).
The following sections describe the steps to adjust the Black mark sensor
(reflex sensor) and the Gap sensors (transparent sensor) in form of flow charts
as well as in form of step by step listings.
*)
Special solution: If the adjusting of the Gap Sync sensor failes because the contrast value
of the label material itself is very low, you can use the panel function
Sync.Sens.Logic
to invert the logic. (Black marks can be used as “inverse gaps” in this way.)