B) Adjusting the Transponder Position (Tag Position) manually :
The transponder position depends on the RFID label type in use.
The following steps describe how to measure the transponder position and how
to configure the printer. To find the optimal setting for your label material, you
have to set/adjust different tag position values and ascertain the RFID reading
results for each position.
(The setting range for the Tag position is 0 up to + 254 mm.)
1.
Take a peace of your label material and use a ruler to measure the
distance between the RFID Inlay and the end of the previous label.
In the following figure the distance to be measured is indicated by a black
arrow.
Fig. 10.2.3.a Measuring the transponder position
(Distance between the RFID-Inlay and the end of the previous label)
2.
Insert your label material
into the printer.
Further details on inserting consumables can be found in chapter 5 Handling
of Consumables.
Feed
direction
RFID Inlay
(Tag)
Distance
End of the
previous label