9.33. Configuration of Network Parameters (IP Address, e.g.)
The functions of the submenu Network are used to set the
parameters for connecting the printer to a network (Ethernet).
Setting the IP address manually:
Panel display
[ON LINE ]
[OFF LINE ]
[Menu Level 1 ]
[Network ]
[Timeout ]
[IP Assign ]
[Off ]
[Manual ]
[IP Address ]
[192.168.002.002
]
[192.168.010.123
]
[Saved ! ]
Notes
Turn the printer OFF LINE with this key.
The ENTER key gives the user access to the
menu structure.
Press the NEXT or PREVIOUS key until
[Network ] is displayed.
Press the ENTER key to select the Network
menu.
Press the NEXT or PREVIOUS key until
[IP Assign ] is displayed.
Press the ENTER key to select the IP Assign
menu.
The currently set configuration is displayed.
Press the NEXT or PREVIOUS key until
[Manual ] is displayed.
Press the ENTER key to set the IP address
manually.
Pushing the UP or DOWN key changes
the value of the current position (left digit
first, in this example: 1). Pressing the NEXT
key moves you to the next digit (the
PREVIOUS key combination moves you
back, if need be).
The new IP address is saved as setup
value.
Turn the printer ON LINE again:
Press the ENTER key longer than
2
seconds.