PlatinumRAID Owner’s Manual
4.1.2 Tagged Command Queuing
The Command Tag (Drive Channel) function controls the command tag queuing support
for the drive channels. Tagged Command Queuing is useful for enhancing overall system
performance under multi-tasking operating systems. This function should normally remain
enabled unless instructed otherwise by MicroNet support.
4.1.3 Max SCSI Speed
The RAID subsystem supports up to 320MB/S as the highest data transfer rate. You may need to
adjust this parameter if you are experiencing SCSI bus stability issues.
4.1.4 SCSI Channel (Reserved)
PlatinumRAID supports one SCSI channel. Do not modify this parameter.
4.1.5 SCSI ID
Each SCSI device on a SCSI device chain, including the host bus adapter, must be assigned a
unique SCSI ID number between 0-15.
4.1.6 SCSI LUN
Each SCSI ID can support up to 8 Logical Units. Logical Units allow multiple logical devices to
share the same SCSI ID and still appear as individual devices to the host.
4.2 Modify Pass Through Disk
To modify the attributes of a pass through disk, choose the
“modify Pass Through”
option.
A table will appear with the available pass through disks. check the radio button next to the
disk to be modified, and modify the desired attributes in the below table (refer to section 4.1
in this chapter for attribute descriptions.) Click the “Submit” Button to finalize.
4.3 Delete Volume Set
To delete a Pass through disk, choose the
“Delete Pass Through”
option. A table will appear
with the available pass through disks. check the radio button next to the disk to be deleted,
and check the box labelled “Confirm the operation.” Click the “Submit” Button.
4.4 Identify Selected Drive
This function is designed to prevent removing the wrong drive by illuminating the selected disk
HDD LED Indicator. To identify selected drive from the physical drive pool, choose the
“Identify
Drive”
option. A table will appear with the available disks. check the radio button next to the
disk to be identified, and click the “Submit” Button. Click the “Reset” button when done.
5. System Controls
5.1 System Configuration Functions
This menu contains various feature and environmental options of the PlatinumRAID. The
following subsections discuss each attribute’s descriptions. When all desired options are
entered, check the box labelled “Confirm the operation” and click the “Submit” Button.
5.1.1 System Beeper Setting
This function enables or disables the RAID subsystem alert buzzer. It is not recommended to turn
the buzzer off as it will not provide audible cues when faults occur.
6-RAID Controls-Web Interface