PlatinumRAID Owner’s Manual
0
attribute to modify and Press
ENT
to modify the default value. Select attribute value and
press
ENT
to accept the selection. After completing the modification, press
ESC
to enter the
confirmation screen and then press
ENT
to accept the Modify Pass-Through Disk function.
4.4 Delete Pass-Through Disk
To delete pass-through drive from the pass-through drive pool, scroll to choose the
“Delete
Pass-Through Drive option”
, and then press
ENT
. The Select Drive Function menu will show
all Pass-Through Drive number items. Select the Pass-Through Disk that user want to delete
and press
ENT
. The Delete Pass-Through confirmation screen will appear. Press
ENT
to
confirm deletion.
4.5 Identify Selected Drive
This function is designed to prevent removing the wrong drive by illuminating the selected
disk HDD LED Indicator. To identify selected drive from the physical drive pool, scroll to
choose the
“Identify Selected Drive”
option
and press
ENT
. Select the Disk to identify
and press
ENT
. The selected disk HDD LED
indicator will flash.
5. RAID System Functions (E)
To control the RAID System, Select the
“RAID
System Function”
option and then press
ENT
to enter further submenus. All RAID system
submenus will be displayed. Scroll to select
the submenus and then press
ENT
to enter
the specified function.
5.1 Mute The Alert Beeper
Select the
“Mute The Alert Beeper”
function to
mute the RAID subsystem alert buzzer. Press
ENT
in the dialog box to turn the beeper off
temporarily. The buzzer will still activate on
any subsequent fault.
5.2 Alert Beeper Setting
The Alert Beeper setting function item is used
to enable or disable the RAID subsystem
controller alarm tone generator. Scroll to
the
“Alert Beeper Setting”
selection and
press
ENT
.
The confirmation screen will be
displayed and then press
ENT
to accept the
function.
5-RAID Controls-LCD/Terminal
E
<Low, Norma l, High>
Wraps Around
<1200,2400...115200>
<1, 2>
Mute the Alert
Beeper
RAID Rebuild
Priority
New Password:
_
Baud Rate
Settings
Number o f Stop
Bit
Select Baud Rate
*115200
Select Stop Bits
*1 Bit
ConfirmCh ange ?
ENT:Yes,ESC:No
Reset The
Controller
Alert Beeper
Setting
Alert Beeper
*Disabled
<Enabled, Disabled>
Confirm Change
ENT:Yes, ESC:No
Change
Password
Confirm Change
ENT:Yes, ESC:No
JBOD/RAID
Function
Operating Mode
*RAID
<RAID,JBOD>
RAID System
Functions
Rebuild Priority
*Low
Confirm Change
ENT:Yes, ESC:No
Confirm Change
ENT:Yes, ESC:No
Maximum SATA Mode
Maximum SATA Mode
*SATA150
<SATA150,NCQ
SATA320, NCQ>
Confirm Change
ENT:Yes, ESC:No
Terminal Mode
Configuration
Truncation Mode
*Off (Reserved)
Confirm Change
ENT:Yes, ESC:No
Truncation Mode
Confirm Change
ENT:Yes, ESC:No
Confirm Change
ENT:Yes, ESC:No
Firmware Update
<Available through Terminal and Web interfaces>
F
HDD Read Ahead
Cache
Read Ahead Cache
*Enabled
<Enabled, Disabled,
Disabled-Maxtor>
Confirm Change
ENT:Yes, ESC:No
Staggered Time
*0.7 (Reserved)
Confirm Change
ENT:Yes, ESC:No
Staggered HDD
Spinup Control
SMART Polling
*Enabled
Confirm Change
ENT:Yes, ESC:No
HDD SMART
Status polling
<Enabled, Disabled>