![MicroNet PlatinumRAID Ultra320 Owner'S Manual Download Page 53](http://html.mh-extra.com/html/micronet/platinumraid-ultra320/platinumraid-ultra320_owners-manual_1787932053.webp)
PlatinumRAID Owner’s Manual
6.2 System Information
Choose this option to display various components of the PlatinumRAID, as illustrated in this
table:
Component
Value
Controller Name
PlatRAID
Firmware Version
V1.39 2006-2-10
BOOT ROM Version
V1.39 2005-12-6
MPT Firmware Version
1.3.39.0
Serial Number
xxx
Unit Serial #
Main Processor
400MHz I80219
CPU ICache Size
32KBytes
CPU DCache Size
32KBytes / Write Back
System Memory
128MB / 200MHz
Current IP Address
192.168.20.164
6.3 Hardware Information
To view the RAID subsystem controller’s hardware monitor information, select the
“Hardware
Information”
option. All hardware environmental information will be displayed. Scroll to browse
all the hardware information. The Hardware Monitor Information provides the temperature,
fan speed (chassis fan) and voltage of the internal RAID subsystem. The temperature items
list the current states of the controller board, backplane, and disk drives.
The Platinum RAID has an audiovisual alert system and remote notification to inform the user
of environmental failure. The warning messages will indicate through the LCD, LED and alarm
buzzer, as well as remote notification as defined in section 5.4 in this chapter. The following
is a table of monitoring threshhold values:
Monitored Item
Warning Condition
Controller Board Temperature
> 60° Celsius
Power 12V
< 10.5V or > 13.5V
Power 5V
< 4.7V or > 5.3V
Power 3.3V
< 3.0V or > 3.6V
DDR Supply V2.5V
< 2.25V or > 2.75V
CPU Core V1.3V
< 1.17V or > 1.43V
SATA Chip +1.2V
< 1.05V or > 1.35V
Controller Fan Speed
< 1900 RPM
HDD #1 Temperature
> 60° Celsius
HDD #2 Temperature
> 60° Celsius
HDD #3 Temperature
> 60° Celsius
HDD #4 Temperature
> 60° Celsius
HDD #5 Temperature
> 60° Celsius
6-RAID Controls-Web Interface