PlatinumRAID Owner’s Manual
3.1.9 SCSI LUN
Each SCSI ID can support up to 8 Logical Units. Logical Units allow multiple logical devices to
share the same SCSI ID and still appear as individual devices to the host.
3.1.10 Max Sync Rate
The RAID subsystem supports up to 320MB/S as the highest data transfer rate.
3.2 Delete Volume Set
Scroll to choose the Delete Existing Volume Set option. Select the RAID set number and
volume set to delete and press
ENT
. At the subsequent confirmation screen, press
ENT
to
confirm deletion.
3.3 Modify Volume Set
Use this option to modify an existing volume set attributes as described in the above section.
To modify volume set attributes scroll to choose the
“Modify Volume Set Attribute option”
from
the
“RAID set system”
function. Select the RAID set number to modify and press
ENT
. Select the
volume set number that user want to modify and press
ENT
. The volume set attributes screen
shows the volume set setting configuration attributes that was currently being configured.
Select attribute to change and Press the
ENT
to modify the default value. Select attribute value
and press the
ENT
to accept the selection value. Choose this option to display the properties
of the selected Volume Set; you can modify all values except the capacity.
Note:
When a volume set is migrating from one RAID level to another, a volume set stripe size changes, or when a disk
is added to a RAID set the volume state will change to migrating. During migration. the migration status will be displayed
in the volume state area of the LCD display. No additional volume changes can be performed until migration completes.
3.4 Check Volume Set Consistency
To check volume set consistency from volume set system function, scroll to choose the
“Check
Volume Set Consistency”
option. Select the RAID set number to check and press
ENT
. Select
the volume set number to check and press
ENT
. At the subsequent confirmation screen, press
ENT
to start the volume set consistency check.
3.5 Stop Volume Set Consistency Check
To stop volume set consistency check from volume set system function, scroll to choose the
“Stop Volume Set Consistency Check”
and then press
ENT
.
3.6 Display Volume Set Information
To display volume set information, scroll to choose the
“Display Volume Information”
option
and then press
ENT
. Select the RAID set number that user wants to show and press
ENT
.
Select the volume set number to display and press
ENT
. The volume set attributes screen
shows the volume set setting configuration value that was currently being configured. See this
chapter, section 3.1-
”
Create RAID Volume Set
”
for the various RAID attribute descriptions.
5-RAID Controls-LCD/Terminal