Precautions And Warnings

 

•  When used in the U.S. use only with supplied Hospital Grade power cord connected to Hospital Grade receptacle 
•  Use only with Microline Cautery Instruments and PowerPack Footswitch. Use of any other instrument may damage the 
instrument/UPS and could prevent it from functioning properly during use 
•  Do not drop the UPS 
•  Do not immerse the UPS in liquids 
•  Do not sterilize the UPS 
•  If using multiple Microline Cautery Instruments, do not allow instruments to contact each other. Do not touch electrosurgical (Bovie) 
electrode to Microline Cautery Instruments. 
•  Procedures using instruments for cutting/cauterization should be performed only by persons having adequate training and familiarity 
with these surgical techniques. Consult the medical literature relative to techniques, complications and hazards prior to performance of 
any procedure. Surgeons using this device should be familiar with the specific anatomy of the region in which they intend to perform the 
procedure.  
•  If using the UltraSlim or SC Forceps device, see Instructions For Use for pre-check information.  
•  There are no user serviceable parts. 

Note

: The UPS is not intended for continuous use. A typical duty cycle of approximately five (5) seconds on, ten (10) seconds off is 

recommended. If the UPS is used continuously, or the instrument connector becomes shorted, the output of the UPS may be 
interrupted. This will be indicated by an absence of audible tone. Attempt to determine the cause of the problem before proceeding. If 
problem cannot be resolved or power is not restored after several minutes of cool-down, contact Microline Surgical for instructions 
regarding repair or replacement of the device. 

Warning

Do not use in the presence of flammable materials (e.g. alcohol, flammable anesthetics). 
Always disconnect the instrument before discarding; the UPS is reusable. 

Electrical Requirements 

Input: 100-240 VAC, 50/60 Hz, 100W 
Maximum Output: 60W  
No Load Voltage: 9V D.C. 

Compliance with Standards 

The UPS complies with IEC60601-1 (UL 2601-1 and CAN/CSA-C22.2 No. 601.1-M90) requirements for type Class I, Type CF 
equipment, Type CF applied parts, and meets electromagnetic compatibility requirements of IEC60601-1-2. Avoid use in the proximity 
of other equipment that may interfere with the proper operation of the UPS. 

Limited Warranty 

Microline Surgical, Inc. warrants that the UPS will be free from defects in materials and workmanship for a period of one (1) year from 
shipment invoice provided that the product is used in accordance with applicable instructions. Products found to be defective during this 
period will be replaced at no charge. Microline makes no other warranties with respect to the product and expressly disclaims all other 
warranties expressed or implied, as to merchantability, fitness for any particular purpose or any other matter. In no event shall Microline 
Surgical, Inc. be liable for consequential damages. 

Symbol Definition 
 

 

Means: Does not Contain Latex. 

 

Means: Temperature

 

Means: On (Power connected to the 

mains). 

 

Means: Footswitch Connector. 

 

Means: Relative Humidity. 

 

 

Means: Atmospheric Pressure. 

 

Means: Off (Power disconnected 

from the main. 

 

Means: Instrument Connector. 

 

Means: Type CF applied Part. 

 

                                                                

 

 

 

 

 

 

 

 

 

                  IFU0035 Rev D 

 

Manufactured under one or more of US patents: 7,033,351; 6,908,463; 6,860,880; 6,695,837; 6,626,901. Patents Pending. All Rights 
Reserved. 
© Copyright 2011, Microline Surgical, Inc. All rights reserved. 
 
 

 

Bloc d’alimentation universel UPS (Universal Power Supply) – Modèles 200-006R / 200-004R – Mode d’emploi  
À utiliser uniquement avec 

Instruments de cautérisation Microline et commande au pied PowerPack™ Microline  

 

Description du dispositif 

Le bloc d’alimentation universel (UPS) modèle 200-006R / 200-004R

 

est non stérile, réutilisable, alimenté par secteur et destiné à être 

utilisé uniquement avec les instruments de cautérisation Microline et a commande au pied PowerPack Microline. L’UPS est destiné à 
être raccordé au secteur par un cordon d’alimentation de qualité hôpitaux mis à la masse, et dispose d’un bouton marche/arrêt et d’un 
voyant d’alimentation vert à DEL.  Selon le dispositif utilisé, un maximum de trois plages de chauffage sont disponibles pour le 
fonctionnement de l’UPS ; celles-ci s’accompagnent d’une tonalité sonore correspondante pour indiquer le niveau d’intensité de 
l’élément de chauffage de l’instrument. Une tonalité sonore à basse fréquence indique l’utilisation d’une chaleur faible. Une tonalité 
sonore intermittente basse indique l’utilisation d’une chaleur variable, et une tonalité sonore fixe à haute fréquence indique l’utilisation d 
niveaux de chaleur élevés. Si l’instrument ne nécessite pas l’utilisation de la commande au pied PowerPack, l’UPS fournit une 
alimentation en chaleur variable uniquement, à moins qu’un dispositif à plusieurs plages de chaleur soit utilisé. L’UPS peut être placé 
sur une surface non stérile plane à côté du champ stérile, ou peut être suspendu sur une potence à perfusion située à proximité. S’il est 
suspendu à une potence à perfusion, l’UPS peut être tourné pour faire face à l’utilisateur.

 

Usage prévu 

L’UPS est destiné à être utilisé uniquement avec les instruments de cautérisation et la commande au pied PowerPack Microline pour 
sectionner et cautériser simultanément les tissus mous au cours de la chirurgie. 
1. Brancher le cordon d’alimentation de qualité hôpitaux mis à la masse sur la prise secteur de l’UPS. 
2. Brancher le cordon d’alimentation sur une prise de qualité hôpitaux mise à la masse.  
3. Aligner l’encoche du connecteur de l’instrument de cautérisation Microline sur la prise de l’UPS et insérer.  
4. Pour utiliser la commande au pied PowerPack, brancher le connecteur de la commande au pied sur la prise de commande au pied 
de l’UPS. 
5. Allumer l’UPS. 
6. Consulter le mode d’emploi de  l’instrument de cautérisation et de la commande au pied PowerPack Microline approprié pour obtenir 
des instructions spécifiques pour le dispositif et les exigences de contrôle préalable. 
7. Modèle 200-006R :

 

Quand l’élément chauffant de l’instrument est activé, l’UPS émet une tonalité sonore qui dure jusqu’à ce que 

l’élément chauffant soit désactivé.  La quantité de chaleur délivrée par l’élément chauffant de l’instrument peut être ajustée en appuyant 
sur la touche « + » ou « - » sur le côté droit de l’UPS. Le réglage numérique est indiqué sur le graphique à barre à DEL situé au-dessus 
des touches.  L’augmentation du réglage numérique augmente la quantité de chaleur délivrée par l’instrument lorsqu’un instrument à 
plage de chaleur fixe est utilisé, ou bien augmente la plage variable lorsque la commande au pied PowerPack en option ou un 
instrument à plage de chaleur variable sont utilisés.  D’une manière générale, une plage de chaleur plus basse augmente la capacité 

FRANÇAIS 

Summary of Contents for 200-004R

Page 1: ...mount of heat delivered by the instrument when using a single heat range instrument or the variable range when using the optional PowerPack Footswitch accessory or multi heat range instrument Generall...

Page 2: ...under one or more of US patents 7 033 351 6 908 463 6 860 880 6 695 837 6 626 901 Patents Pending All Rights Reserved Copyright 2011 Microline Surgical Inc All rights reserved Bloc d alimentation uni...

Page 3: ...minimum Mises en garde et avertissements Lors de l utilisation aux tats Unis utiliser uniquement avec le cordon d alimentation de qualit h pitaux fourni raccord une prise de qualit h pitaux Utiliser u...

Page 4: ...chiave del connettore dello strumento di cauterizzazione Microline con la presa del connettore dell UPS e inserire 4 Se si intende usare la pedaliera PowerPack inserire il connettore della pedaliera...

Page 5: ...uso continuo Si raccomanda un ciclo di servizio di circa cinque 5 secondi di servizio e dieci 10 secondi di pausa Se l UPS viene usato ininterrottamente o il connettore dello strumento cortocircuitato...

Page 6: ...b der Drucktasten angezeigt Durch Erh hen der Einstellung des numerischen Werts wird die von dem Instrument abgegebene Hitze erh ht wenn ein Instrument mit einfachem Hitzebereich oder der variable Ber...

Page 7: ...1 A max Ausgang max 60 W Spannung ohne Last 9 V Gleichstrom Einhaltung der Normen Das Netzger t erf llt die Anforderungen von IEC60601 1 UL 2601 1 und CAN CSA C22 2 Nr 601 1 M90 f r Ger te der Klasse...

Page 8: ...ntervenci n quir rgica apagar el UPS posici n Off y desconectar el instrumento cauterizador de Microline y si corresponde el Conmutador de pedal PowerPack Manipulaci n almacenamiento y limpieza No dej...

Page 9: ...veau van het verwarmingselement op het instrument aangeven Bij gebruik van laag vermogen lage temperatuur wordt een laag geluidssignaal gegeven Een onderbroken laag geluidssignaal geeft aan dat er var...

Page 10: ...te zijn met het anatomisch gebied waarin ze de ingreep wensen te verrichten Raadpleeg bij gebruik van het UltraSlim of SC Forceps instrument de gebruiksaanwijzing voor informatie over de inspectie v r...

Page 11: ...006R N r instrumentets varmeelement aktiveres afgiver den universale str mforsyningsenhed en tone der vedvarer indtil varmeelementet deaktiveres Den m ngde varme der leveres af instrumentets varmeelem...

Page 12: ...ks effekt 60W Hvilesp nding 9V j vnstr m Overensstemmelse med standarder Den universale str mforsyningsenhed er i overensstemmelse med kravene i IEC60601 1 UL 2601 1 og CAN CSA C22 2 Nr 601 1 M90 for...

Page 13: ...nesteisiin Ymp rist olosuhteet Kuljetus S ilytys K ytt 15 50 C 15 30 C 15 30 C 25 95 30 85 45 75 700 1060 hPa 700 1060 hPa 700 1060 hPa T m n laitteen asianmukaiseen h vitt miseen ei liity mit n ep t...

Page 14: ...rst ende intraven sstativ Dersom UPS enheten henger fra et intraven sstativ kan den roteres slik at den vender mot brukeren Tiltenkt bruk UPS enheten er beregnet til bruk kun med Microlines kauterise...

Page 15: ...eller erstattes av brukeren Merknad UPS enheten er ikke beregnet p kontinuerlig bruk En typisk driftssyklus p omtrent fem 5 sekunder p ti 10 sekunder av anbefales Dersom UPS enheten brukes kontinuerl...

Page 16: ...r nda tills v rmeelementet inaktiveras M ngden v rme som levereras av instrumentets v rmeelement kan justeras genom att man trycker p eller p n taggregatets h gra sida Den numeriska inst llningen ange...

Page 17: ...regatet uppfyller kraven enligt IEC60601 1 UL 2601 1 och CAN CSA C22 2 nr 601 1 M90 f r utrustning av klass I typ CF och uppfyller kraven p elektromagnetisk kompatibilitet enligt IEC60601 1 2 Undvik a...

Page 18: ...auteriza o Microline e se aplic vel o Interruptor a Pedal PowerPack Manuseamento Armazenamento e Limpeza N o deixe cair Armazene em lugar fresco e seco Evite exposi o prolongada a temperaturas extrema...

Page 19: ...i a t i provozn teplotn rozsahy s odpov daj c mi t ny indikuj c mi v kon topn ho t lesa n stroj T n s n zkou frekvenc indikuje pou it n zk ho ru P eru ovan t n indikuje pou v n p eru ovan ho ru a nep...

Page 20: ...im nebo SC Forceps postupujte podle kontroly p ed pou it m uveden m v n vodu k pou it V tomto za zen nejsou dn sou stky na kter ch m e u ivatel prov d t servis Pozn mka UZN nen ur en k nep etr it mu p...

Page 21: ...ry trwa b dzie do czasu jego dezaktywacji Ilo dostarczonego ciep a z grzejnika instrumentu mo na ustawia przyciskami z symbolami or po prawej stronie zasilacza UPS Ustawienia numeryczne pokazane s na...

Page 22: ...mocy UPS Wska e na to brak sygna u Przed dalszym post powaniem nale y ustali przyczyn problemu Je eli problemu nie mo na rozwi za lub przywr ci mocy po kilku minutach ch odzenia nale y skontaktowa si...

Page 23: ...8 200 004R UPS UPS PowerPack 9 UPS off Microline PowerPack UPS UPS 15 C 50 C 15 C 30 C 15 C 30 C 25 C 95 30 C 85 45 C 75 700hPa 1060hPa 700hPa 1060hPa 700hPa 1060hPa 200 006R 1 2 LED 3 4 5 6 LED 7 On...

Page 24: ...0035 D 7 033 351 6 908 463 6 860 880 6 695 837 6 626 901 Copyright 2011 Microline Surgical Inc UPS 200 006R 200 004R Microline Microline PowerPack Footswitch UPS 200 006R 200 004R AC Microline UPS LED...

Page 25: ...UPS UPS Microline Bovie Microline UltraSlim SC Forceps UPS 5 10 UPS UPS Microline Surgical UPS 100 240 AC 50 60 100 60 9 DC UPS IEC60601 1 UL 2601 1 and CAN CSA C22 2 No 601 1 M90 Class I CF CF IEC60...

Page 26: ...s kijelz se Egyszeres h m rs klet tartom ny k sz l kn l vagy pedig az opcion lis PowerPack l bkapcsol tartoz k eset n v ltoztathat tartom nyn l illetve t bbsz r s h m rs klet tartom ny k sz l kn l a L...

Page 27: ...bel l a t pell t s nem ll vissza vegye fel a kapcsolatot a Microline Surgical c ggel a k sz l k jav t s ra vagy cser j re vonatkoz utas t sok rt Figyelmeztet s Tilos gy l kony anyag jelenl t ben haszn...

Page 28: ...UPS UPS 15 C 50 15 C 30 15 C 30 25 95 30 85 45 75 700 1060 700 1060 700 1060 200 006R 1 2 3 4 5 6 7 8 9 10 200 004R 1 2 3 4 5 6 A UPS HAR 250 VAC 2A 3 x 0 75 mm2 minimum Microline PowerPack UPS UPS U...

Page 29: ...S IEC60601 1 UL 2601 1 CAN CSA C22 2 No 601 1 M90 I CF t CF IEC60601 1 2 UPS Microline Surgical Inc UPS 1 Microline Microline Surgical Inc CF IFU0035 Rev D 7 033 351 6 908 463 6 860 880 6 695 837 6 62...

Page 30: ...A G 4 1 6 9 19 9 9AB 3 5 6 1 5 78 9 9 L N P 7 200 006R 9 B E G H 01 0 4 2 7 7 1 4 5 1 95 5 4 C E 1 01 0 1 23 4 4 54 B H 54 0 89 AB 1 56 1 4 8 200 004R 8 9 A 9 D F G 3 56 7 5 5B B 0 7 B H I B J K L 78...

Page 31: ...lim SC 6 9 B D 3 3 3 5 3 5 10 34 7 9 4 7 G I OP 4 4 4 78 4 4BC 4 4 G7 H 3 7 D D G K DM 4 2 4 5 0 04 7 9 4 100 240 50 60 100 60 9 0 1 0 14 IEC60601 1 1UL 2601 1 CAN CSA C22 2 601 1 M90 I 12 CF 1 8 IEC6...

Page 32: ...daha d k s aral klar cihaz n kapatma yetene ini ve doku divizyon s resini artt r r Y ksek s aral klar divizyon s resini k salt r ve kapat lan dokunun b t nl n azaltabilir 8 Model No 200 004R Aletin s...

Page 33: ...anestetikler bulundu u yerlerde kullanmay n Aleti atmadan nce daima ba lant lar n kesin GK tekrar kullan labilir Elektrik Gereksinimleri Giri 100 240 VAC 50 60 Hz 100W Maksimum k 60W Y ks z Voltaj 9V...

Reviews: