5. Technical Data
ThermiStar L .. SP 01/03/10
30
Electrical controller data
Input
(Controller)
Rated voltage
AC 230 V (
±
10%)
Rated frequency
50/60 Hz
Max. power consumption
11 VA
Fuse protection of supply lines
max. 10 AT
Wire gauge
internal resistance
1 wire: 1.0 mm
2
- 1.5 mm
2
> 100 k
Ω
Terminal
wiring
(Outputs)
Wire or stranded wire (twisted or with wire end
ferrule):
1 wire: 0.5 mm
2
...2.5 mm
2
2 wires 0.5. mm
2
..1.5 mm
2
Function data
Mode of functioning according to EN 60730
1b (automatic function)
Inputs
Digital inputs H1, 3
Extra-low voltage for potential-free extra-low
voltage capable contacts:
Voltage at open contact: DC 12 V
Voltage at closed contact: DC 3 mA
Analog input H1, 3
Extra-low voltage
Operating range: DC (0...10) V
Internal resistance: > 100 k
Ω
Line inputs EX1…EX7, E9-E11
AC 230 V (
±
10 %)
Internal resistance > 100 k
Ω
Sensor input B9
Sensor inputs B1, B3, B4, B21, B41, B71, B81,
B82, B91 und B92
Sensor inputs BX1…BX5
NTC1k (QAC34)
NTC10k (QAZ36, QAD36)
NTC10K (QAZ36, QAD36), PT 1000
Permitted sensor lines (Cu)
At wire gauge:
Max. length:
0.25 0.5 0.75 1.0 1.5
(mm
2
)
20 40 60 80 120
(m)
Outputs
Relay outputs Q2, Q3, Q8, Q9, QX1..QX6, Y1,
Y2
Rated current range
Max. starting current
Max. total current (of all relays)
Rated voltage range
AC 0.02...2 (2) A
15 A during
≤
1 s
AC 6 A
AC (24...230) V (for potential-free outputs)
Output Q4 Mod rated current range
ON/OFF operation
Speed control
Max.
starting
current
AC 0.05...2 (2) A
AC 0.05...1.4 (1.4) A
4 A during
≤
1 s
Analog output UX
Output voltage
Current
load
Ripple
Accuracy at zero point
Faults remaining range
Output is short circuit-proof
Uout = 0 ... 10.0 V
±2 mA RMS; ±2.7 mA peak
≤
50 mVpp
< ± 80 mV
≤
130 mV
Summary of Contents for 98.30000-6324
Page 1: ...ThermiStar L SP 01 03 10 ...
Page 18: ...5 Technical Data ThermiStar L SP 01 03 10 18 5 2 Type plate Fig 4 Sample type plate ...
Page 21: ...ThermiStar L SP 01 03 10 5 Technical Data 21 ...
Page 39: ...ThermiStar L SP 01 03 10 6 Assembly 39 Fig 11 Sensor cable heat source intake 5 ...
Page 68: ...8 Maintenance ThermiStar L SP 01 03 10 68 8 4 Spare part drawing and legend Fig 40 ...
Page 88: ...Your notes ThermiStar L SP 01 03 10 88 ...
Page 89: ...ThermiStar L SP 01 03 10 Your notes 89 ...
Page 90: ...Your notes ThermiStar L SP 01 03 10 90 ...
Page 92: ......