ThermiStar L .. SP 01/03/10
6. Assembly
47
Fig. 19:
Electrical connection
Legend for terminal diagram electrics board:
1
4
7
10
13
16
19
22
25
28
Con
den
se
r
pump L
Heat source
pump/ventilat
or
L
---
Spec
ial tariff
L1
Wi
ndi
ng
prote
ction INT
69L
---
Normal tariff L
Solenoid liq
ui
d
line L
Solenoid
heater L
Solenoid
thawin
g L
2
5
8
11
14
17
20
23
26
29
Con
den
se
r p
ump
N
Heat source
pump/ventilat
or N
Spec
ial tariff N
Spec
ial tariff L2
P
res
su
re s
w
itch
high pressu
re
L
P
res
su
re s
w
itch
high pressu
re
Normal tariff N
Solenoid liq
ui
d
line N
Solenoid h
eat
er
N
Solenoid tha
w
ing
N
3
6
9
12
15
18
21
24
27
30
Con
den
se
r p
ump
PE
Heat source
pump/ventilat
or
PE
Spec
ial tariff PE
Spec
ial tariff L3
P
res
su
re s
w
itch
low pressu
re
L
P
res
su
re s
w
itch
low pressu
re
Normal tariff PE
Solenoid liq
ui
d
line PE
Solenoid h
eat
er
PE
Solenoid tha
w
ing
PE
The electrical connection is made according to the wiring diagram in
chapter 5.4.
The circuit protection in the distributor (meter cabinet) must be made
with a 3-pole power circuit breaker (C-characteristics) according to
the output ratings of the heat pump. The potential equalization is to
be connected at the M6 or M8 connecting screw marked for this
purpose.
Summary of Contents for 98.30000-6324
Page 1: ...ThermiStar L SP 01 03 10 ...
Page 18: ...5 Technical Data ThermiStar L SP 01 03 10 18 5 2 Type plate Fig 4 Sample type plate ...
Page 21: ...ThermiStar L SP 01 03 10 5 Technical Data 21 ...
Page 39: ...ThermiStar L SP 01 03 10 6 Assembly 39 Fig 11 Sensor cable heat source intake 5 ...
Page 68: ...8 Maintenance ThermiStar L SP 01 03 10 68 8 4 Spare part drawing and legend Fig 40 ...
Page 88: ...Your notes ThermiStar L SP 01 03 10 88 ...
Page 89: ...ThermiStar L SP 01 03 10 Your notes 89 ...
Page 90: ...Your notes ThermiStar L SP 01 03 10 90 ...
Page 92: ......