50
Analysis. Typical tasks and solutions
5.10
OAM
An important task is to provide high quality of administrating and main-
tenance for Ethernet-networks. To regulate these tasks the IEEE 802.3ah[8]
standard (also known as
Ethernet in the First Mile (EFM) OAM
) has been
worked out.
OAM (Operations, Administration, and Maintenance) is a protocol of
monitoring the link state. The protocol operates at the Data Link Layer of
OSI model. To transmit data between two Ethernet-devices, OAM protocol
data units (OAMPDU) are used.
An important feature of the OAM protocol is providing the ability to use
Loopback mode for the remote end. Both devices should support the IEEE
802.3ah standard.
To establish connection between
Bercut-ET
and remote device via OAM
protocol and to switch on Loopback mode it is necessary to execute the fol-
lowing actions.
•
Connect
Bercut-ET
and remote device directly in accordance with
fig. 5.49 given below.
physical connection
remote device
loopback
Figure 5.49. OAM testing scheme
On the remote device:
•
Enable OAM protocol function in active or passive mode.
On the local device:
•
Switch to the
OAM
menu (see fig. 5.50).
•
In the menu item
Port
select port the remote device is connected to.
•
In the menu item
Mode
select active operating mode of OAM protocol.
•
The discovery state of the remote device must be
Send any
.
•
Switch to the
Remote device
menu. Information about remote device
will be displayed on the screen.
Bercut-ET. Operations manual
Summary of Contents for Bercut-ET
Page 6: ...6 Bercut ET Operations manual ...
Page 8: ...8 Bercut ET Operations manual ...
Page 10: ...10 Bercut ET Operations manual ...
Page 12: ...12 Bercut ET Operations manual ...
Page 18: ...18 Bercut ET Operations manual ...
Page 65: ...5 12 Testing TCP IP 65 Figure 5 68 Response example Bercut ET Operations manual ...
Page 96: ...96 Bercut ET Operations manual ...
Page 102: ...102 Bercut ET Operations manual ...
Page 114: ...114 Bercut ET Operations manual ...