5 Electrical installation
Pin X6
Name
Specification
1
MT+
Motor temperature
2
MT-/ DSL-
Motor temperature sensor -
3
BR+
Holding brake +
4
BR-
Holding brake -
5
DSL+
Pin assignment: motor connector (HIPERFACE DSL
®
)
Figure 20: Pin assignment: „motor connector (HIPERFACE DSL
®
) [X6], [X6A]“
Pin X6A Name
Specification
1
U
Motor phase U
2
V
Motor phase V
3
W
Motor phase W
Pin X6
Name
Specification
1
MT+
2
MT-/ DSL-
HIPERFACE DSL -
3
BR+
Holding brake +
4
BR-
Holding brake -
5
DSL+
HIPERFACE DSL +
Cable type and configuration [X6] und [X6A]
The cable names that are stated refer to cables made by Lapp. However, it is also
possible to use comparable cables from other manufacturers, for example Lütze or
Helukabel.
X6: LAPP UNITRONIC LiYCY (TP) 2x2x0,75
X6A: ÖLFLEX CLASSIC 135 CH 3G4
Mounting Instructions BL 4000-M and BL 4000-D