CLI Notification
Alarm events
On this page you can set up different notification types for a number of events. This
is an important feature because of the nature of a timeserver: running in the
background. If an error or problem occurs, the timeserver is able to notify an
administrator by using a number of different notification types.
The LANTIME timeserver offers four different ways of informing the administrator
or a responsible person about nine different events: EMAIL send an e-mail message
to a specified e-mail account, SNMP-TRAP sends a SNMP trap to one or two SNMP
trap receivers, WINDOWS POPUP MESSAGE sends a Winpopup message to one or
two different computers and DISPLAY shows the alarm message on a wall mount
display model VP100/NET, that is an optional accessory you can obtain from us.
Here is a table of all events:
"NTP not sync"
NTP is not synchronised to a reference time source
"NTP stopped"
NTP has been stopped (mostly when very large time offsets
occur)
"Server boot"
System has been restarted
"Receiver not responding"
No contact to the internal GPS receiver
"Receiver not sync"
Internal GPS clock is not synchronised to GPS time
"Antenna faulty"
GPS antenna disconnected
"Antenna reconnect"
GPS antenna reconnected
"Config changed"
Configuration was changed by a user
„Leap second announced“
A leap second has been announced
“TIME LIMIT ERROR”
SHS detected time difference
85
Summary of Contents for LANTIME
Page 1: ...Technical Information Operating Instructions LANTIME SHSPZF ETX BGT...
Page 47: ...Configuration Ethernet 47...
Page 52: ...Configuration Notification 52...
Page 56: ...Configuration Security 56...
Page 69: ...Configuration Local 69...
Page 77: ...Configuration Statistics 77...
Page 110: ...Rear View LANTIME 110...
Page 111: ...SUB D Connector Assignments 111...
Page 113: ...Accuracy of frequency TCXO quartz standard 113...
Page 132: ...Menu Quick Reference 132...
Page 145: ...IRIG Standard Format 145...
Page 146: ...AFNOR Standard Format 146...