SETUP SERIAL PORT
This menu lets the user configure the baud rate and the framing of the serial RS232
port to one of the following values:
Baud Rate:
300 to 19200
Framing:
7E2, 8N1, 8E1, 8O1
COM provides a time string once per second or once per minute.
Default:
COM: 19200 baud, 8N1, once per second
The following modes are possible:
Per Second:
Time string will be send to next change of second
Per Minute:
Time string will be send to next change of minute
On Request:
Time string will be send if an '?' will be send to this port
SETUP
SERIAL PORT
SERIAL PORT
PARM: 9600 8N1
MODE: Per second
SETUP SERIAL STRING TYPE
This topic is used to select one of several different types of serial time strings or the
capture string for each serial port.
The following time strings can be selected:
- Meinberg Standard String
- GPS167 Capture String
- SAT String
- UNI-Erlangen String
- NMEA String (RMC)
- SPA String
- Computime String
SETUP
SER. STRING TYPE
SER. STRING TYPE
COM: Meinbg Std
Refer to chapter
Time Strings
for details.
39
Summary of Contents for LANTIME
Page 1: ...Technical Information Operating Instructions LANTIME SHSPZF ETX BGT...
Page 47: ...Configuration Ethernet 47...
Page 52: ...Configuration Notification 52...
Page 56: ...Configuration Security 56...
Page 69: ...Configuration Local 69...
Page 77: ...Configuration Statistics 77...
Page 110: ...Rear View LANTIME 110...
Page 111: ...SUB D Connector Assignments 111...
Page 113: ...Accuracy of frequency TCXO quartz standard 113...
Page 132: ...Menu Quick Reference 132...
Page 145: ...IRIG Standard Format 145...
Page 146: ...AFNOR Standard Format 146...