Technical Specifications Power Supply Unit PULS AP 336-505
INPUT
VOLTAGE:
105 ... 300 V DC, max. 0.7 A
85 ... 265 V AC, 47... 63 Hz, max. 1.5 A
FUSE:
Electronic
OUTPUT
VOLTAGES:
Vout1:
5.15 V / 2 A
Vout2:
+12 V / 1 A
Vout3:
-12 V / 1 A
Minimum load of the 5 V output when control accuracy of the
12V outputs should be smaller than 4 %: 100 mA
TOTAL
SAVE LOAD:
Max. 35 Watt
TYPE OF
CONNECTOR:
Male connector according to DIN 41612, type H15, pre-mating
protective contact
MOUNTING
FRAME:
19" module 3U / 9HP (128 mm high x 45 mm wide), according
to DIN 41494, part 5
EMC-conform to EN 60950
Front Panel and Rear Connector Pin Assignments
d z
32
30
28
26
24
22
20
18
16
14
12
10
8
6
4
GND 1
+Vout 1
+Vout 1
GND 1
GND 2/3
NC
NC
Pfl
Vout 2
Vout 3
GND 2/3
NC
N (GNDin)
L (Vin)
PE
123