Safety instructions for building-in equipment
This building-in equipment has been designed and tested in accordance with the
requirements of Standard IEC 950 "Safety of Information Technology Equipment,
including Electrical Business Equipment".
During installation of the building-in equipment in an end application (i.e. rack)
additional requirements in accordance with Standard IEC 950 have to be taken into
account.
o The building-in equipment is a class 1 - equipment and must be connected to an
earthed outlet (TN Power System).
o The building-in equipment has been evaluated for use in office environment
(pollution degree 2) and may be only used in this environment. For use in
rooms with a higher pollution degree more stringent requirements are
applicable.
o The building-in equipment may not be opened.
o Protection against fire must be assured in the end application.
o The ventilation opening may not be covered.
o The equipment/building-in equipment was evaluated for use in a maximum
ambient temperature of 40 °C.
o For safe operation the building-in equipment must be protected by max 16 A
fuse in the power installation system.
o Disconnection of the equipment from mains is done by pulling the mains plug.
CE-Label
EN 60950
Safety of Information Technology Equipment,
including Electrical Business Equipment
Electromagnetic compatibility
EN50081-1
Electromagnetic compatibility (EMC). Generic emission
standard. Part 1: Residential, commercial and light industry
EN50082-2
Electromagnetic compatibility (EMC). Generic immunity
standard. Part 2: Industrial environment
108
Summary of Contents for LANTIME
Page 1: ...Technical Information Operating Instructions LANTIME SHSPZF ETX BGT...
Page 47: ...Configuration Ethernet 47...
Page 52: ...Configuration Notification 52...
Page 56: ...Configuration Security 56...
Page 69: ...Configuration Local 69...
Page 77: ...Configuration Statistics 77...
Page 110: ...Rear View LANTIME 110...
Page 111: ...SUB D Connector Assignments 111...
Page 113: ...Accuracy of frequency TCXO quartz standard 113...
Page 132: ...Menu Quick Reference 132...
Page 145: ...IRIG Standard Format 145...
Page 146: ...AFNOR Standard Format 146...