Configuration of the timeserver with SNMP: Reference
The MIB of the timeserver includes the following parts:
SNMP Object
Name
Description
enterprises.5597
mbgSNMP
Root node of the Meinberg-MIB
mbgSNMP.3
mbgLantime
Root node of the LANTIME MIB
mbgLantime.1
mbgLtNtp
LANTIME NTP status variables
mbgLantime.2
mbgLtRefclock
LANTIME reference time source status
variables
mbgLantime.3
mbgLtTraps
LANTIME SNMP traps
mbgLantime.4
mbgLtCfg
LANTIME configuration variables
mbgLantime.5
mbgLtCmd
LANTIME control commands
Further detailed information can be found in the Meinberg MIB files.
Reference of LANTIME SNMP configuration variables:
SNMP branch
Variable
Data type
Description
mbgLtCfgNetwork
mbgLtCfghostname
string
The hostname of the timeserver
mbgLtCfgDomainname
string
The Domainname of the timeserver
mbgLtCfgNameserver1
string (IPv4 or IPv6-
address)
IP-address of first nameserver
mbgLtCfgNameserver2
string (IPv4 or IPv6-
address)
IP-address of second nameserver
mbgLtCfgSyslogserver1
string (IPv4 or IPv6-
address or
hostname)
IP-address or hostname of first syslog-
server
mbgLtCfgSyslogserver2
string (IPv4 or IPv6-
address or
hostname)
IP-address or hostname of second
syslog-server
mbgLtCfgTelnetAccess
integer (0 =
disabled, 1 =
enabled)
Telnet access activated?
mbgLtCfgFTPAccess
integer (0 =
disabled, 1 =
enabled)
FTP-access activated?
mbgLtCfgHTTPAccess
integer (0 =
disabled, 1 =
enabled)
Webinterface activated?
mbgLtCfgHTTPSAccess
integer (0 =
disabled, 1 =
enabled)
Encrypted webinterface activated?
mbgLtCfgSNMPAccess
integer (0 =
disabled, 1 =
enabled)
SNMP-daemon activated?
mbgLtCfgSambaAccess
integer (0 =
disabled, 1 =
enabled)
LANManager-access activated?
mbgLtCfgIPv6Access
integer (0 =
disabled, 1 =
enabled)
IPv6-protocol enabled?
mbgLtCfgSSHAccess
integer (0 =
disabled, 1 =
enabled)
SSH-access activated?
mbgLtCfgNTP
mbgLtCfgNtpServer1IP
string (IPv4 or IPv6-
address or
hostname)
First external NTP-server
mbgLtCfgNtpServer1KEY
integer
Link to the key which should be used
for the first NTP-server
mbgLtCfgNtpServer2IP
string (IPv4 or IPv6-
address or
hostname)
Second external NTP-server
mbgLtCfgNtpServer2KEY
integer
Link to the key which should be used
for the second NTP-server
mbgLtCfgNtpServer3IP
string (IPv4 or IPv6-
address or
hostname)
Third external NTP-server
102
Summary of Contents for LANTIME
Page 1: ...Technical Information Operating Instructions LANTIME SHSPZF ETX BGT...
Page 47: ...Configuration Ethernet 47...
Page 52: ...Configuration Notification 52...
Page 56: ...Configuration Security 56...
Page 69: ...Configuration Local 69...
Page 77: ...Configuration Statistics 77...
Page 110: ...Rear View LANTIME 110...
Page 111: ...SUB D Connector Assignments 111...
Page 113: ...Accuracy of frequency TCXO quartz standard 113...
Page 132: ...Menu Quick Reference 132...
Page 145: ...IRIG Standard Format 145...
Page 146: ...AFNOR Standard Format 146...