11.4 Cleaning instruction – weekly
We recommend that the following cleaning operations are undertaken each week
in addition to the daily cleaning.
Do not use a high pressure cleaner!!!
Press the “OFF” button for
the final cleaning cycle.
After approx. 15 min. this
cycle is terminated
automatically.
(Operating panel AZP 80)
Press the EMERGENCY
STOP switch off!
(Operating panel AZP 80)
Open drain valve.
Open the tank cover and the cleaning door of the wet waste press. Flush out the interior
of the press. Open the the cover of the wet waste press.
Remove the screen tube and the worm spindle and pull
them apart. Both parts can now be cleaned easily, e.g.
on the floor plate.
(Important! A second person may have to help owing to
the weight of the parts. Beware of shearing and crushing
points when assembling the worm spindle and screen
tube!)
Lift the flap and use a water
hose to flush out the tank
and the shredding
mechanism, if possible with
warm water.