2. See Figure 10. When all groups of fixtures are connected correctly,
connect a Martin cable-mounted 13-pin DIN male DMX
Termination Plug (P/N 91611336) in the DMX output of the last
fixture of each separate chain of fixtures.
Figure 10: DMX termination plug
3. For DMX control and remote configuration via MUM, connect a
DMX Input Adapter to the Power Inserter.
4. Use a three-wire power cable, cable diameter based on the lengths
below.
Total Length
Cable specification
1 - 15 m
(3.3 - 49 ft.)
IP66 extension cable or
16 AWG or 1.5mm
2
15 - 40 m
(49 - 131 ft.)
14 AWG or 1.5mm
2
40 - 80 m
(131 – 262 ft.)
12 AWG or 2.5mm
2
5. Use CAT5 or better data cable.
6. See Figures 11 and 12. If you need to extend the distance
between fixtures, use a set of Tripix Cable Adapters, IP66,
Male+Female (P/N 91611323).
7. When installing fixtures outdoors or in a wet or damp environment,
install each cable adapter inside an IP66-rated electrical junction
box (not provided). Ensure that all cable grommets are completely
sealed against moisture and dust. Failure to seal the box can lead
to damage and risk of electric shock! Use only cable and junction
boxes that are approved for installation and conform to all local
Summary of Contents for Tripix