Tripix user manual
Testing
See Figure 28.The
LED Test
window in MUM gives a quick method of
testing LED output at 100% intensity without a DMX controller:
Figure 28: LED test window
Fuse replacement
DANGER! Lock out power to the entire distribution system before
servicing or opening any cover. Replace fuses with ones of the
same type and rating only. Do not attempt to bypass a fuse.
The Tripix Power is protected by a 6.3 amp slow-blow primary fuse. If
the Tripix Power is completely dead, the primary fuse may have blown.
To replace the fuse:
1. Disconnect the Tripix Power from power and allow to cool.
2. See Figure 29. Open the fuseholder located next to the power
cable entry with a flathead screwdriver and remove the fuse.
3. Replace the fuse with one of the same type and rating. Fuse
ratings are listed on serial number labels and under “Electrical” on
page 39.
4. Replace the fuseholder.
5. If fuses continue to blow, there is probably a fault. Disconnect the
device from power and data and contact a Martin service
technician for assistance.